Configuring converters / Function test
MasterCAN RS2CAN / CAN2RS data converters. Operation manual. Version 1.0
©
Technoton, 2020
42
3.10 Function test
configuration and connection have been performed correctly, the device
operation starts from the moment the power is on. When the power supply is off, the converter
operation stops.
During the converter operation the LED indicators located on its front panel must be on
(see table 7). Also, the converter must provide converted data into the respective output
interface.
Table 7
–
Designation of signals of the converters LED indicators
LED Indicator
Signal description
Marking
Status
Light color
POWER
Green
Power supply is on
No signal
Power supply is off (or voltage is less
than minimum required)
For model
MasterCAN RS2CAN
RS 485
Red
Data reception from the input
RS-485 interface
Connection failure
CAN1
Red
Data transmission to the output
CAN interface
Connection failure
For model
MasterCAN CAN2RS
CAN1
Red
Data reception from the input
CAN interface
Connection failure
RS 485
Red
Data transmission to the output
RS-485 interface
Connection failure