Version 5.0 DUT-E Installation Manual
© 2007-2011, JV Technoton 15 of 30
2.5 Length increasing
Length increasing is carried out by attaching of DUT-E additional section to the measuring
part.
Model range of DUT-E additional sections include: KDC 250, KDC 500 and KDC 1000 with
lengths of 250, 500 and 1000 mm correspondingly.
Fig.11. Additional section of DUT-E
Length increasing of analog and frequency DUT-E sensors is possible
only
for restoring the
length after cutting and
only
within limits of the DUT-E nominal length.
Length increasing for digital DUT-E sensor is allowed to a length of 6000 mm.
The detailed information for the mounting process is contained in the operation manual for
DUT-E additional section.
Extra sections of DUT-E can be cut to the desired length. When cutting you should follow
the recommendations given in item 2.4 of this guide.
2.6 Mounting
To provide extra stiffness to the sensor you need to install bottom spring stop (which is a
part of delivery set) on the end of the measuring part of the DUT-E. Just put the bottom
spring stop on the tube and fix to it by tightening the screws at the end of the bottom
spring stop.
In order to fix the DUT-E it is necessary to put an O-ring right on the dap of the mounting
plate, and then put the sensor into the hole (see Fig. 12), press it with force and lock by
turning clockwise till sealing holes of the DUT-E housing and mounting plate come together
(see Fig. 13).
ATTENTION!
During installation it is recommended to apply a small amount of oil or fuel
on the O-ring of the mounting plate so that to prevent its deformation when you fix the
DUT-E inside the mounting plate.