UNICA EVOLUTION: Service & Maintenance Manual - rev. 1.1
10.3.2. M
INIMUM
ROM
LENGTH
This item configures the minimum displacement of the weight stack, in cm, before the movement is
considered a repetition. The display shows:
CONFIGURATION
MINIMUM ROM LENGTH
CM X
Insert number
10
.
10.3.3. D
EFAULT
ROM
START
This item configures the distance in cm that the weight stack must move from the rest position
before entering the exercise zone. This distance depends on the mechanics of the individual
machine. Typically, this displacement is achieved using the machine’s easy-start lever. The display
shows:
CONFIGURATION
DEFAULT ROM START
CM XX
Insert number
1
.
10.3.4. D
EFAULT
ROM
LENGTH
This item configures the default value of the ROM, in cm, prior to acquisition of the user’s personal
ROM, and is used to correctly fill out the ROM LED band on the display. The display shows:
CONFIGURATION
DEFAULT ROM LENGTH
CM XX
Insert number
34
.
10.3.5. %ROM
FIRST REP
This item sets the percentage of the ROM, as defined in the parameter “default ROM length”,
which is performed using the machine’s easy start lever during the first repetition. The display
shows:
Page 10.11
Summary of Contents for Unica Evolution
Page 1: ...SERVICE MAINTENANCE MANUAL Rev 1 1...
Page 2: ......
Page 4: ......
Page 14: ...UNICA EVOLUTION Service Maintenance Manual rev 1 1 Page 3 4 Page intentionally left blank...
Page 16: ...UNICA EVOLUTION Service Maintenance Manual rev 1 1 Page 4 2 Page intentionally left blank...
Page 24: ...UNICA EVOLUTION Service Maintenance Manual rev 1 1 Page 7 2 Page intentionally left blank...
Page 30: ...UNICA EVOLUTION Service Maintenance Manual rev 1 1 Page 8 6 Page intentionally left blank...
Page 56: ...UNICA EVOLUTION Service Maintenance Manual rev 1 1 Page 10 24 Page intentionally left blank...
Page 58: ...UNICA EVOLUTION Service Maintenance Manual rev 1 1 Page 11 2 Page intentionally left blank...
Page 59: ......