BIKE XT: Service & Maintenance manual - rev. 2.0
Page 4.1
4.
ACCESSORIES
4.1.
CONNECTING TO THE TGS
The machine can be connected to the Technogym System by means of the 9-pin D-type connector
situated on the back of the display, which provides the RS 232 serial port for connecting the TGS
reader.
The serial port is connected to the CPU by the cable described below, which is supplied in the
upgrade kit:
TGSRN2XT: Internal cable
CPU – 9 pin connector
CPU/CN2
Signal
Color
DB9 male
1
+ 12 V
yellow
1
2
Tx
brown
3
5
Rx
white
2
6
ground
green
5
To prevent interference with the cardio receiver, route the cable behind cable BX-1 and
connector CN1 of the CPU board.
For all further information, including troubleshooting, refer to the following manual: “Technogym
System: Installation Guide”.