Transmitter AG-105 Technical specifications
The frequencies of the continuous «Co» or pulse «Pu» signal, Hz ± 0,1% - «kHz»
Load
«clips»
or
«clamp»
512
- «0.5» /
1024
- «1.0» /
8192
- «8.2» /
32768
- «33»
«Antenna»
modes
8192
- «8.2» /
32768
- «33»
Operating modes
«Antenna»
modes
Internal transmitting inductor «
In
».
External induction transmitting antenna «
An
».
«Modulation»
modes (special
form signal)
Pulse «
Pu
» (short-term transmissions of the sine signals).
Transmission duration 0,12sec.
Transmissions repetition frequency 1Hz.
Dual-frequency «
2F
» (simultaneous frequency generation 1024Hz, 8192Hz).
Amplitudes ratio 4/1 (respectively).
Output parameters under power supply voltage 12…15V
Output current, А
Restricted by the program
under
manual increment,
≥
5
– at frequency 512Hz «0.5» / 1024Hz «1.0» / 8192Hz «8.2» / «2F»
3
- at frequency 32768Hz «33»
Set by the program for
automatic adjustment
with
the external load of «clips» or
«clamp»,
≥
0,2
– at frequency 512Hz «0.5» / 1024Hz «1.0» / «2F»
0,1
– at frequency 8192Hz «8.2» / 32768Hz «33»
Maximum output voltage, V
Depending on «modulation»,
≥
32
– in the dual-frequency modulation mode «2F»
40
– in other modes
Maximum output power, W
Restricted by the program,
≥
20 -
In the continuous «Co» and pulse «Pu» modes at frequencies 512Hz
«0.5» / 1024Hz «1.0» / 8192Hz «8.2» at load resistance up to 80
Ω
In dual-frequency mode «2F» at load resistance up to 50
Ω
.
6
- At frequency 32768Hz «33» at load resistance up to 260
Ω
.
Power supply sources
Operating range of the supply
voltages
Minimally acceptable voltage for oscillation start-up -
7V.
Maximum allowed voltage for operation –
15V.
Automatic shutdown voltage in the “oscillation” mode <
4,2V.
Battery
set
8 «alkaline» cells 1,5V «type С»
Recommended – «Duracell ® ULTRA».
External
power supply sources
(optional)
Battery
«12V» (e.g. automotive)
Output voltage 11…14V, maximum current not less than 4А.
Mains power supply adapter
АG114М.02.020 (extra accessory based on
GS60A15-P1J «MEAN WELL»)
Output voltage 15V, power 60W.
Operating time («life cycle»)
While in operation of the battery set «type Сх8» is defined by the quality
(capacity and «load capability») of the applied alkaline cells and can be equal
to
from 4 to 6 hours in the «Co» и «2F» modes or from 20 to 30 hours
in the «Pu» mode
at initial output voltage 7W in «continuous» modes «Co» /
«2F» or at initial output voltage 15W in pulse modulation mode «Pu».
Under the external power supply is fully conditioned by this external energy
source characteristics therefore
under mains supply operating time is
unlimited.