Setting of the receiver for the active search. «Route» mode
Turn
on the
power
Press
‘Enter’
button to
open the
menu
To confirm
your selection
press ‘Enter’
button.
Select
the icon
«Modes» in
the menu.
buttons
Select the «Route»
mode
buttons
Procedure for search of communication and conduction of cable route location
1. Connect the generator to
the communication by contact
or contactless method.
When possible, the
preference should be given
to the contact method of
connection, which allows
to perform the cable route
location for more distantly.
2. Turn on the generator. Set the signal type
- impulse
«IM»
/continuous
«CS»
The generation
frequency on the generator - 512, 1024, 8192, 32768
Hz.
Impulse mode (IM)
It is used to increase the
time of work of generator.
Continuous signal (CS)
allows to conduct
simultaneously with the routing the diagnostic of
the faults of the power cable
Note
Note
The example of setting of parameters on the
generator.
3. Start the
generation, wait
for the transmitter
to power up.
4. Proceed with the
setting of the receiver
AP-019.1.
Example
Press ‘Enter’
again to
return to
main menu.
To confirm
your selection
press ‘Enter’
button.
Select «Filter» in
the menu.
buttons
Set the filter
frequency
corresponding
to the transmitter
frequency, for
example 1024 Hz.
buttons