Technica Engineering CM Eth Combo User Manual Download Page 52

 

 
 

CM Eth Combo 

User Manual

  

52 

 

Figure 5-4:Power and BroadR-Reach Connector for Capture Module

 

 

 

Figure 5-5: MediaGateway connection in detail 

 

Note:

  It  is  recommended  to  use  our  *.cfg-file  for  the  MediaGateway  configuration.   

With this configuration the Media Gateway forwards the data from the S2-P5 directly 
to the BR-S2-P0. 
 

Summary of Contents for CM Eth Combo

Page 1: ...Manual Version 0 992 Hardware v1 0 up to v3 1 USER MANUAL January 2020 IVN2Eth Capture Module CM Eth Combo Firmware v009 00x 060...

Page 2: ...ckside 12 pins 2 rows 12 2 1 4 MATEnet connectors Backside 2x 13 2 1 5 USB mini connector 14 2 2 Other Interfaces 14 2 2 1 Rotary Switch 14 2 2 1 1 Rotary Switch in status 0 to D 15 2 2 1 2 Rotary Swi...

Page 3: ...1 10 Edit Basic Filter 33 4 5 1 11 Edit Advance Filter 35 4 5 2 Host Port 37 4 5 3 GB Ports 38 4 5 4 100BASE T1 Ports 40 4 5 5 1000BASE T1 Ports 42 4 6 Synchronisation of several devices by PTP 802 1A...

Page 4: ...CM Eth Combo User Manual 4 6 ADDITIONAL INFORMATION 54 7 LIST OF FIGURES 55 8 CHANGELOG 56 9 CONTACT 57...

Page 5: ...twork and delivered with a 40 ns resolution hardware time stamp thus making the analysis of AVB TSN traffic possible Several devices can be used on the same setup whenever more T1 ports are needed and...

Page 6: ...tion Power requirement 8 to 18 Volt DC nominal 12 Volt DC Power consumption 5 5 to 6 6 Watt Size 137 x 129 x 33 mm Weight 0 8 kg International Protection IP 2 0 Operating temperature 40 Celsius to 80...

Page 7: ...Special care has to be taken for operation Do not use this device in a series production car As this device is likely to be used under rough conditions warranty is limited to 1 year Manufacturer liabi...

Page 8: ...aration of Conformity Figure 1 2 Copy of Declaration of conformity 1 4 Scope of Delivery The delivery includes 1x CM_Eth_Combo Cable set can be ordered separately 1x Cable set o 1m Ethernet Cable o co...

Page 9: ...0 2 4 not available anymore V3 0 and higher Advantages of second version Better performance due to temperature issue Start up much faster More internal space for buffering Note there are different sof...

Page 10: ...User Manual 10 2 HARDWARE INTERFACES 2 1 Connectors On the label on top of the device you can see an overview about all HW Interfaces of the CM_Eth_Combo Figure 2 1 Label of CM_Eth_Combo with pinning...

Page 11: ...olt the device will be damaged In this connector there are also two wakeup lines As a digital input each wake up line consumes approx 0 7 mA As digital output each wake up line supplies max approx 60...

Page 12: ...Ethernet connectors There are two RJ45 Standard Ethernet connectors on the front side for Gigabit Ethernet Here you can log and configure the device And these ports are for time synchronization betwee...

Page 13: ...ool for PSK contacts Pin Function Pin Function 1 100 BASE T1 2B Minus 7 100 BASE T1 2A Plus 2 100 BASE T1 2B Plus 8 100 BASE T1 2A Minus 3 n c 9 n c 4 n c 10 n c 5 100 BASE T1 1A Minus 11 100 BASE T1...

Page 14: ...Plus Table 2 6 Pinning of Tyco Mate Net Connector 2 1 5 Micro HDMI connector This is an interface for programming and debugging only for development 2 2 Other Interfaces 2 2 1 Rotary Switch The follo...

Page 15: ...ss is valid even there is a power reset or the Rotary Switch has been changed and is switched back to E The valid IP address in this Rotary Switch position is part of the PLP header if PLP is activate...

Page 16: ...st be repaired LED H The Host LED can toggle at two different speeds o Slow toggle approx 1 sec during normal operation o Fast toggle approx 0 2 sec if device is in Bootloader mode Right side 2 These...

Page 17: ...100BASE T1 Port to the Microcontroller and the IP address 192 168 0 49 as default This port is configured as 100BASE T1 slave as default 1 Please go to the network adapter settings and adjust the IP a...

Page 18: ...ke all wished changes and save the configuration at the end Please check the box restart after saving and then press the Save configuration button After the restart all changes are applied 4 2 Home Sc...

Page 19: ...nd the bootloader You see the configured IP addresses The version number registers of the switch and PHY chips are displayed for information If these registers are displayed as FFFFFFFF this port PHY...

Page 20: ...Port is displayed here Serial number The Serial number of the CM_Eth_Combo is displayed here 4 3 2 IP addresses Figure 4 4 IP addresses There are two possibilities to access to the device Access by 1...

Page 21: ...the Rotary Switch It is not configurable except in Rotary Switch status E For more information please see CHAPTER 2 2 1 Please type the new IP address in the field After leaving the focus of this fie...

Page 22: ...gure 4 6 Restart device This is useful for discarding not saved changes 4 4 2 Configuration Figure 4 7 handling of configuration files Change Configuration name Here you can change the name of the con...

Page 23: ...press the button Import then you have to choose the file extension of the configuration file and click on that button Note Import as json file please be aware that there can be needed more than one j...

Page 24: ...onsumption is reduced to zero and only the wake up lines in the black Power Connector at the frontside can wake up the CM_Eth_Combo More information can be found in CHAPTER 4 4 3 1and CHAPTER 4 5 Keep...

Page 25: ...ides the same voltage as the voltage on the powerline kind of loop through It provides power as long as there is a reason to stay awake WakeUp Line 1 Actuator If this box is unchecked this wakeup line...

Page 26: ...ground The starting point of timecounter is the same time as there is no reason anymore to be awake of the CM_ETH_Combo itself Default value is 10 seconds 4 4 6 Sleep Timeout Figure 4 12 Sleep Timeou...

Page 27: ...MM DDThh mm ss After typing please press Note If no time is set the time starts from powerup with default value Note If device is shut down by power reset or fell into status Sleep Date and Time setti...

Page 28: ...Switch Status tab Figure 4 14 Switch Status tab This is an overview of all ports A blue bar indicates the linkup on this port If you select a port or any other part of the CM_Eth_Combo it is shown by...

Page 29: ...ed and logged data is encapsulated in a new ethernet frame with the original captured ethernet frame as payload PLP protocol is deactivated and logged data is sent to the logging port without encapsul...

Page 30: ...but with outerVlan An outerVlan will be added in the captured frame The additional bytes are four bytes The first two bytes are 0x9100 as ethertype and the second two are your configured section at t...

Page 31: ...er wakeup Linkup is not respected Available only as single choice 802 1AS Master detected If this box is checked logged data will be sent after a PTP Master is detected on the logging port If there is...

Page 32: ...e 4 16 Overview Filters Table The Filters Table shows an overview about the basic filters in current picture no filter shown These basic filters can be edited by the button Edit Table The button Edit...

Page 33: ...hows the user Interface Figure 4 17 Filters Table Close Edit Leave the Edit screen of Filters Table Clear table this button deletes all Filter Entries Please press Apply after clearance Add new entry...

Page 34: ...ce MAC Address MAC_DST Destination MAC Address ETH_TYPE Ethertype Note Each Bus Parameter to filter pair is possible only for once Value One value in defined format must be typed in this field IN_VLAN...

Page 35: ...e Filter When you press the button Edit Advance Filter FIGURE 4 16 you can apply different advance filters for the captured data FIGURE 4 19 shows the user Interface Figure 4 19 User interface advance...

Page 36: ...s independent from the standard logging port Output to from BASE T1 Port The data is only logged on selected ports Parameter Parameter is used in chosen Action User Event It specifies the UserEventID...

Page 37: ...XX IP Msg Dest IPv4 XXX XXX XXX XXX Source UDP Port XXXX hex Destination UDP Port XXXX hex ARP Sender IP XXX XXX XXX XXX ARP Target IP XXX XXX XXX XXX Subtype AVTP 1 bye XX hex Stream ID AVTP 8 bytes...

Page 38: ...unication CM_Eth_Combo can t go asleep This port is not supervised The Capture Module can fall asleep even there is communication on this port 4 5 3 GB Ports These ports are for logging and time synch...

Page 39: ...can fall asleep even there is communication on this port Cascade to None forwarding of incoming traffic GB A forwarding of incoming traffic to GB A GB B forwarding of incoming traffic to GB B 802 1AS...

Page 40: ...d information to this GB port BR 1A means OABR 1A does not send its logged information to this GB port 4 5 4 100BASE T1 Ports Figure 4 22 100BASE T1Port Port name Port name of every 100BASE T1 Port ca...

Page 41: ...ecific GB Port Note Don t forget to configure the field Maximal delay bytes for Injection No Injection possible on this port IP for Injection This field is available if the box Enable Injection for th...

Page 42: ...mpliance with 1000BASE T1 and 100BASE T1 Phy Mode Here you can choose compliance with IEEE or A0 Phys from Marvel IEEE IEEE compliant Legacy Working in Configuration of A0 Phy from Marvel Output to He...

Page 43: ...forget to set IP for Injection on the specific GB Port Note Don t forget to configure the field Maximal delay bytes for Injection No Injection possible on this port IP for Injection This field is ava...

Page 44: ...re this communication is established only between two devices Time aware system i 1 configured as 802 1as master and Time aware system i 1 configured as slave the ports of the CaptureModule Time aware...

Page 45: ...e correction adjust of the time reference transmitted by the Sync and Follow Up Packets the delay between the initiator of the protocol Time aware system i 1 and the first slave port of CaptureModule...

Page 46: ...e next rule will be used in the following row and no change of Port and Action is possible It will be counted as two rules You must start with an open bracket any time With the buttons and you can nav...

Page 47: ...he BASE T1 port by a device on the logging port a few preconditions are necessary Only one device can inject on one GB Port For the Inject the DUT on the BASE T1 ports has to be connected directly on...

Page 48: ...e the IP Address of the DUT_2 Of course the Box Enable Injection for this port must be checked and the Maximal delay bytes for Injection must be filled out 512 1024 or max 1536 If you have enabled the...

Page 49: ...e 12 Volt DC power supply Do not switch off the power supply during the update process Notes You need administration privileges on your Windows system to do the firmware update on the CM_ETH_Combo Mak...

Page 50: ...dress please interrupt by closing the cmd window Then make a power reset and correct the IP address in the batch file The HOST LED should blink fast Restart update process 5 Wait until Press any key a...

Page 51: ...re 5 2 Schematic with MediaGateway Figure 5 3 Example of MediaGateway and Capture Module CM_ETH_Combo assembly Connect the Ethernet Cable to the Converter or to the MediaGateway FIGURE 5 5 and that de...

Page 52: ...each Connector for Capture Module Figure 5 5 MediaGateway connection in detail Note It is recommended to use our cfg file for the MediaGateway configuration With this configuration the Media Gateway f...

Page 53: ...192 168 0 49 4 Connect a Windows PC with a RJ45 cable directly to MediaConverter or MediaGateway and make sure there is a link by checking the LEDs blinking Do not connect a switch in between 5 Start...

Page 54: ...ser Manual 54 6 ADDITIONAL INFORMATION The CM_Eth_Combo is optimized for automotive use The maximum cable length for 100BASE T1 segments is limited to 15 meters Hardware v2 4 requires at least firmwar...

Page 55: ...Time 27 Figure 4 13 Switch Status tab 28 Figure 4 14 Spy multiplexer Overview no Filters set 29 Figure 4 15 Overview Filters Table 32 Figure 4 16 Filters Table 33 Figure 4 17 User interface basic fil...

Page 56: ...CM Eth Combo User Manual 56 8 CHANGELOG Version Chapter Description Date 0 991 All Draft Version 12 2019...

Page 57: ...roduct please feel free to contact us Technica Engineering GmbH Leopoldstr 236 80807 M nchen Germany Technical support support technica engineering de General information Info technica engineering de...

Reviews: