CM Eth Combo
User Manual
39
Working as Config-port
:
You can configure the Capture Module by this port with your configuration-PC.
The status messages of the Capture Module are transmitted on this port. (for
details have a look to the PLP-protocol). Port GB-A is default Config-Port. Port GB-
A is also Config-port if no port is configured as Config-port.
You
don’t get access to the Webserver of the Capture Module by
this port. The
status messages of the Capture Module are not transmitted on this port.
Working as DLT-port
:
If you want to establish a TCP-Connection on this port to any connected device on the
BASE-T1 ports, you have to activate this function. Please also configure the
IP for
Injection
. For further information please see
C
TCP-Connection possible
TCP-Connection not possible
Keep Awake Reason Bus
:
This port is supervised. If on this port is communication, CM_Eth_Combo can’t go
asleep.
This port is not supervised. The Capture Module can fall asleep even there is
communication on this port.
Cascade to
:
None
: forwarding of incoming traffic
GB-A
: forwarding of incoming traffic to GB-A
GB-B
: forwarding of incoming traffic to GB-B
802.1AS mode
:
Disabled
: there is no synchronisation with other PTP-partners
Bridge Slave
: the connected device on this port must be a bridge master of ptp-
protocol
Bridge Master
: the connected device on this port must be a bridge slave of prp-
protocol
802.1AS Master
: This port is generating the master clock for the logging system
Note
: Ports configured as Bridge Master or bridge Slave can be cascaded as well
Note:
If there is already one port defined as Bridge-slave there is no more a Bridge-
Slave-port or 802.1AS Master-port possible.
IP for Injection
: If you want to get direct access to a device connected on a BASE-T1
Port by this GB-Port through a TCP-connection, you must apply here the IP-address of
the connected device on this GB-
Port. Don’t forget to do this
on the BASE-T1 port, too.
If the function
Use PLP for Header
on SPY multiplexer is activated (see
C
HAPTER
). P
lease don’t forget to set a
n
Advance filter
with logging
without PLP
for the