2.2.1.1
Rotary-Switch in status 0 to D
The IP-addresses are not configurable by software or by any user interface and can
only be changed by using the rotary switch. It is overtaken after 500ms by a software
reset. The current IP-address is shown on the System Information tab. Access to the
CM_Eth_Combo is given through the defined configuration port or 100BASE-T1 Port
on the Frontside (Host).
The set IP-address is part of the PLP header if PLP is activated.
2.2.1.2
Rotary-Switch in status E
The IP address 10.104.3.142 is the default IP-address. In this Rotary-Switch status the
IP-address is configurable on the System Information tab. The configured IP-address
is valid even there is a power reset, or the Rotary-Switch has been changed and is
s
witched back to “E”
. The valid IP-address in this Rotary-Switch position is part of the
PLP header if PLP is activated.
2.2.1.3
Rotary-Switch in status F
The IP address 10.104.3.143 is the default IP-address. It is not configurable. The IP-
address is not overtaken after changing the rotary switch from any position to position
“F”. There will be no software reset. A power reset is needed. But i
f there is a power
reset in this Rotary-Switch status, the CM_Eth_Combo will be reset to out of the box
status.
Complete
configuration will be lost and set to default.
To get access again by another IP-address, once a power reset is needed in another
Rotary Switch position than “F”.