Page
27
of
43
Note:
In the case of CAN, LIN and FlexRay, the generated Ethernet frame will be sent only if the
Header is enabled in
Spy Multiplexer
(see section 5.4.2).
The following table shows the values of
Ethertype
field:
Protocol
Value
BroadR-Reach
0x2082
FlexRay
0x2083
LIN
0x2084
CAN
0x2085
The following table shows the values of
Port
field when
Ethertype
is 0x2082 (BroadR-Reach frames):
Port
Value
BR 1A
0x01
BR 1B
0x02
BR 2A
0x03
BR 2B
0x04
BR 3A
0x05
BR 3B
0x06
BR 4A
0x07
BR 4B
0x08
BR 5A
0x09
BR 5B
0x0A
BR 6A
0x0B
BR 6B
0x0C
The following table shows the values of
Port
field when
Ethertype
is 0x2085 (CAN frames):
Port
Value
CAN A
0x01
CAN B
0x02
CAN C
0x03
CAN D
0x04
CAN E
0x05
In the case that the
Ethertype
value is 0x2083 (FlexRay frames) or 0x2084 (LIN frames), the
Port
field
will be 0x01.