5.6 - PARAMETERS - DISPLAYING AND ADJUSTING

5.6.1 - GENERAL

• Parameter access is structured within a multi-level menu, see the diagram below. Simultaneously pressing the

"

ON/OFF

" (

1

) and "

Mode

" (

2

) buttons for a brief moment (less than 2 seconds) gives access to the next level.

Simultaneously pressing for a long moment (longer than 2 seconds) turns you to the previous level.

• Button (

1

) or button (

2

) is used to scroll through the entries ("Label") within the same level or to increase or decrease a

parameter value.

5.6.2 - PARAMETER ACCESS DIAGRAM

t < 2 sec. -->  Upper level

t > 2 sec. --> Return to the 

previous level

(*) Accessible to qualified personnel only after entering the password (PSS).

Note 1: 

Indicator lamps (

6

), (

7

), (

8

) flash when levels 1 and above are accessed.

Note 2: 

The normal display (level 0) returns automatically after 5 minutes if no buttons are pressed.

Level 0

Normal display

Level 1

Level 2

Level 3

Level 4

Temperature S1
Alarm active

Set value SET

Heating setpoint
HEA

Setpoint value

Temperature 
probes  TP

Probe code  t01…t04

Temperature value

Alarms Err

Alarm code E00...

Digital inputs Id (*)

Input code 01…

input status

Parameters PAr (*)

Config. para. CnF

Parameters codes
H01…

Parameter value

Compressor
parameter CP

Parameters codes
C01…

Parameter value

Fan parameter FAn

Parameters codes
F01…

Parameter value

Alarm parameter
ALL

Parameters codes
A01…

Parameter value

Pump para. PUP

Parameters codes
P01…

Parameter value

Frost. para. Fro

Parameters codes
r01…

Parameter value

Defrost. para. dFr

Parameters codes
d01…

Parameter value

Password PSS

Password value

Hour counters OHr

Comp. counter 1 OH1

Counter value

Pump counter OHP

Counter value

Summary of Contents for PHT 13

Page 1: ...aldamento Fluido refrigerante R 407 C Bomba de calor de alta temperatura con equipamiento hidr ulico s lo calefacci n Fluido refrigerante R 407 C Hochtemperatur W rmepumpe mit Hydraulikmodul Nur Heize...

Page 2: ...humidity of the ambient air very quickly This can modify its lubricant properties and lead in time to the destruction of the compressor MAINTENANCE INSTRUCTIONS 1 Never add oil to the appliance the c...

Page 3: ...lation check that its power supply is disconnected and locked out 1 4 USE OF EQUIPMENT This device is designed for heating buildings This appliance is not designed to be used by people including child...

Page 4: ...st not be directed towards surrounding windows vibrations and noise must not be transmitted to a nearby building avoid exposure to salty air or sulphuric gas the proximity of the extractor fan project...

Page 5: ...he table below Note The unit is designed to be connected to a power supply having a TT neutral regime neutral to ground or TN S regime to neutral as per NF C 15 100 POWER SUPPLY CABLE Section see tabl...

Page 6: ...f a safety delay is in progress It stays on when the compressor is operating The control probe SD1 is located on the water inlet in the factory The controller is connected on a printed circuit board o...

Page 7: ...paragraph 5 4 If the light flashes it means that the compressor is starting required but that a safety delay is in progress This light stays on when the compressor has started To stop the unit open t...

Page 8: ...s 1 and above are accessed Note 2 The normal display level 0 returns automatically after 5 minutes if no buttons are pressed Level 0 Normal display Level 1 Level 2 Level 3 Level 4 Temperature S1 Alarm...

Page 9: ...tions Go to the PSS section in the menu Briefly and simultaneously press buttons 1 and 2 The message appears Enter the password using buttons 1 and 2 and validate it by simultaneously pressing buttons...

Page 10: ...tor lamp 7 Note The ventilation can restart after defrosting is completed to prevent excessive pressure build up For special climatic conditions the factory set time counter value of 30 minutes can be...

Page 11: ...a time delay system in order to respect a maximum number of starts per hour 10 a minimum stop time Cycle inversion valve The valve is actuated during defrost cycles Control hysteresis See the operati...

Page 12: ...ssure 2 bar That there are no leaks That the machine is stable That the power cables are well fixed to their connection terminals Terminals that are poorly tightened may cause overheating and malfunct...

Page 13: ...nal exchangers casings and the cleaning and protection of condensate tanks Treating odours and the disinfection of room surfaces and volumes also contributes to the cleanliness of the air breathed by...

Page 14: ...n the spare parts list for replacing defective refrigeration components Pipes may only be replaced by copper tubing in compliance with standard NF EN 12735 1 Leak detection in the case of pressure tes...

Page 15: ...8 16 4 14 4 51 4 59 19 64 23 70 26 19 17 4 20 4 60 4 69 19 67 23 70 26 19 18 4 25 4 69 4 78 19 70 23 70 26 19 19 4 31 4 79 4 88 19 73 23 70 26 20 20 4 36 4 88 4 97 19 77 23 70 26 20 21 4 40 4 93 5 02...

Page 16: ...4 53 4 76 20 08 23 98 26 56 17 4 28 4 62 4 85 20 09 23 98 26 55 18 4 36 4 71 4 94 20 10 23 98 26 53 19 4 43 4 79 5 03 20 12 23 98 26 52 20 4 51 4 88 5 12 20 13 23 98 26 50 21 4 55 4 92 5 16 20 13 23...

Page 17: ...apacitor C11 M11 capacitor C3 Filter E1 High pressure switch E2 Low pressure switch EV1 Electrovalve J1 Water differential pressure switch KA1 Phase sequence controller KM2 Contactor compressor KM3 Ci...

Page 18: ...F GB D P I E...

Page 19: ...F GB D P I E...

Page 20: ...dificarli senza preaviso En el inter s de mejoras constantes nuestros productos pueden modificarse sin aviso pr vio Unsere Produkte werden laufend verbessert und k nnen ohne Vorank ndigung abge ndert...

Reviews: