Indoor Unit KPA128R5TAA
Outdoor Unit GR129R5TBA
COOLING
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230V 1-phase 50Hz
Rating Conditions Running Amps. A 0.29 0.28 5.03 5.6
Power Input kW 0.07 0.062 1.088 1.22
Full Load Conditions Running Amps. A 0.29 0.28 6.43 7.0
Power Input kW 0.07 0.062 1.388 1.52
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
HEATING
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230V 1-phase 50Hz
Rating Conditions Running Amps. A 0.29 0.28 5.53 6.1
Power Input kW 0.07 0.062 1.188 1.32
Full Load Conditions Running Amps. A 0.29 0.28 7.43 8.0
Power Input kW 0.07 0.062 1.578 1.71
Rating Conditions
: Indoor Air Temperature 20°C D.B.
Outdoor Air Temperature 7°C D.B. / 6°C W.B.
Full Load Conditions : Indoor Air Temperature 27°C D.B.
Outdoor Air Temperature 24°C D.B. / 18°C W.B.