28
Indoor Unit MCAV97R5VAA
Outdoor Unit GR99R5TBA
COOLING
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 230V 1-phase 50Hz
Rating Conditions Running Amps. A 0.12 0.24 4.05 4.4
Power Input kW 0.027 0.055 0.888 0.97
Full Load Conditions Running Amps. A 0.12 0.24 4.74 5.1
Power Input kW 0.027 0.055 1.068 1.15
Rating Conditions : Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
HEATING
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 230V 1-phase 50Hz
Rating Conditions Running Amps. A 0.12 0.24 3.85 4.2
Power Input kW 0.027 0.055 0.868 0.95
Full Load Conditions Running Amps. A 0.12 0.24 4.19 4.55
Power Input kW 0.027 0.055 0.925 1.007
Rating Conditions : Indoor Air Temperature 20°C D.B.
Outdoor Air Temperature 7°C D.B. / 6°C W.B.
Full Load Conditions : Indoor Air Temperature 27°C D.B.
Outdoor Air Temperature 24°C D.B. / 18°C W.B.