2. SPECIFICATIONS
2-1. Unit Specifications
Symbol of indoor unit : SEE INSTALLATION INSTRUCTION OUTDOOR UNIT
Power Source 220 – 240 V ~ 50 Hz
Cooling
Max.Capacity
kW
5.5
BTU/h
20,000
Indoor unit(s)
A + B
C
A + B + C
Capacity
kW
3 2.5 5.5
BTU/h
10,900
9,000
20,000
Voltage rating
V 230
Available voltage range
V
198 to 264
Running amperes
A 5.0 4.2 9.2
Power input
W
1,100 1,000
2000
Power factor
%
95 95
95
C.O.P.
W/ W 2.7 2.5
2.8
Compressor locked rotor amperes
A
24
24
48
Fan speed
1
Compressor
Rotary (Hermetic)
Refrigerant / Amount charged at shipment
g
R407c / A + B : 950 C : 950
Refrigerant control
Capillary tube
Operation sound
dB-A
54
Refrigerant tubing connections
Flare type
Max. allowable tubing length at shipment
m
A + B : 15 C : 7.5
Refrigerant tube
Narrow tube
mm (in.)
A , B , C : 6.35 (1/4)
diameter
Wide tube
mm (in.)
A , B , C : 9.52 (3/8)
Refrigerant tube kit
Optional
Dual system kit
Non
GRV227M3C5
Unit dimensions
Height
mm
630
Width
mm
830
Depth
mm
305
Package dimensions
Height
mm
713
Width
mm
994
Depth
mm
413
Weight
Net
kg
61.0
Shipping
kg
66.0
Shipping volume
m
3
0.29
Dimensions & Weight
Features
Electrical Rating
Performance
Outdoor Unit GRV227M3C5
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks: Rating conditions are:
Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
1.
Unit Combination
Combine indoor and outdoor units only as listed
in the installation instruction outdoor unit
4
1.
1
OPERATING RANGE
Temperature
Indoor Air Intake Temp.
Outdoor Air Intake Temp.
Cooling
Maximum
32°C D.B. / 23°C W.B.
43°C D.B.
Minimum
19°C D.B. / 14°C W.B.
19°C D.B.