2-3. Other Component Specifications
Outdoor Unit GRV227M3C5 GRV340M3C5
Relay:
MCS24A2F1
Coil rating
AC 240V
Coil resistance
k
Ω
(at 20°C)
15.5 ± 15%
Contact rating
AC 250V, 5A
Power Relay (PR1,PR2)
G7L-2A-TUB
Coil rating
AC 220/230/240V, Single Phase 50Hz
Coil resistance
Ω
(at 23°C)
21 ± 15%
Contact rating
AC 220V, 25A
Thermostat (Fan Speed Control)
YTB-4U201F
Switching temp.
°C
high
→
LOW
24°C
low
→
HIGH
26°C ± 1.5
+ 1.5
– 0.5
Timer (T)
(UNTIL 31/12/2002 MODEL GRV227M3C5
H3Y-2
Rating
AC 220V, 50/60Hz
Operating time
3 minutes
Solenoid Valve:
NEV-MOAJ503B0 (Coil), NEV202DXF (Valve)
Rating
AC 240V, 50/60Hz
7/6W, 45/35mA
Coil resistance
k
Ω
(at 20°C)
1.15
±
7
%
(SAP – CMR3448E only)
GRV227M3C5 (R1,2) GRV340M3C5(R1,2 and R3,4)
GRV227M3C5(SVA,B)GRV340M3C5(SVA,B,C,D)
PCB
Timer
(FROM 01/01/2003 MODEL GRV227M3C5
PCB TIMER
Rating
AC 220V, 50/60Hz
Operating time
3 minutes
10
Dual System Kit DKR5555C DKR8585C
Relay (R1, R2)
( UNTIL 31/12/2002 )
MY2-02-US-TS
Coil rating
AC 240V
Coil resistance
Ω
(at 20°C)
650 ± 15%
Contact rating
AC 240V, 4.4A
Solenoid Valve (SV)
NEV-MOAJ503B0 (Coil), NEV202DXF (Valve)
Rating
AC 240V, 50/60Hz
7/6W, 45/35mA
Coil resistance
k
Ω
(at 20°C)
1.15
±
7
%
Timer (T)
( UNTIL 31/12/2002 )
H3Y-2-0
Rating
AC 200–230V, 50/60Hz
Operating time
3 minutes
(SVC1,C2)
PCB TIMER ( FROM 31/12/2002 )
PCB TIMER
Rating
AC 200–230V, 50/60Hz
Operating time
3 minutes