background image

EG

Use DRY operation when you want to reduce the humidity
in the room.

Once the room temperature reaches the set level, the unit
repeats the cycle of turning on and off automatically.

During DRY operation, the fan speed is automatically set
(Remote control lamp             is ON) to prevent overcooling.

Dry operation is not possible if the indoor temperature is
10 °C or less.

8

ADJUSTING THE FAN SPEED

AUTOMATIC

Simply set the FAN selector to the        position.A
microcomputer automatically controls the fan speed when
the AUTO mode is selected. When the air conditioner starts
operating, the difference between the room temperature
and the set temperature is detected by the microcomputer
which then automatically switches the fan speed to the
most suitable level.

NIGHT MODE / ENERGY SAVING

This mode enables you to save energy.

1. Set the MODE selector to cool, dry or heat.

2. Press the NIGHT button.

3. The          mark appears on the display. Press the NIGHT

button again to release the NIGHT function.

What does the NIGHT mode mean?
When you select the NIGHT mode, the air conditioner will
modify automatically the set temperature after 60 minutes.
This enables you to save energy without sacrificing your
comfort.

NOTE

FAN ONLY

If you want to make air circulate without any temperature
control, follow these steps:

1. Press the ON/OFF operation button and switch the air

conditioner ON.

2. Press MODE button until only the             fan sign

appears on the display.

The above mentioned data make reference to the
conditioner operating when the sensor on the remote control
unit is ON. (Refer to temperature sensor selector). If the
sensor on the indoor unit is being used then actual operation
will slightly differ from that described in the above tables.
The automatic speed is not available in FAN ONLY mode.

NOTE

WHEN DIFFERENCE BETWEEN

ROOM TEMPERATURE AND SET

FAN SPEED

TEMPERATURE IS

Cooling and

2 °C and over

High

dehumidifying 

Between 2 and 1 °C

Medium

modes:

Below 1 °C

Low

2 °C and over

High

Heating mode:

Below 2 °C

Medium

High speed

Med. speed

Low speed

MANUAL

If you want to manually adjust speed just set the FAN selector
as desired.

OPERATING MODE

SET TEMPERATURE CHANGE

Heating

Lowered by 1 °C

Cooling and Dehumidifying

Raised by 2 °C

During the NIGHT mode the internal fan speed is
automatically lower and reduces the noise. 

NOTA

S

elezio

n

e f

un

zio

n

e

Temperat

u

ra ambie

n

te

1 h

TEMPO

1°C

COOLING AND DEHUMIDIFYING

HEATING

S

elezio

n

e f

un

zio

n

e

Temperat

u

ra ambie

n

te

1 h

TEMPO

2°C

HIGH POWER MODE

When this mode is active the internal fan speed is set
automatically and the air conditioner operates, for 15
minutes, at the maximum power. After 15 minutes from the
selection  the symbol         on the display switch off and the
mode is automatically switched off.

NOTE

During the high power operation the room temperature
could not correspond to the set temperature. 

FILTER Ti0

2  

(if present)

Pressing the FILTER button (symbol           on the display)
the filtering system with titanium dioxide is activated; this
is very effective to prevent bad odours and to eliminate
bacteria and micro-organisms. 

NOTE

The filter is active only if the internal fan is operating. 

Function selection

Room temperature

TIME

Function selection

Room temperature

TIME

Summary of Contents for CA8FIA0R5I

Page 1: ...3 01 10 2010 Split air conditioner system Condizionatore d aria split system Climatiseurs split Split klimager t Acondicionador de aire de consola partida sistema split MTA8FIA0R5I MTA8FBI0R5I KPA8FIA...

Page 2: ...product is marked as it satisfies Directives Low voltage no 2006 95 CE Electromagnetic Compatibility no 89 336 EEC 92 31 EEC and 93 68 EEC This declaration will become void in case of misusage and or...

Page 3: ...Remote control receiver This section picks up infrared signals from the remote control unit Transmitter 6 Operation selector without remote control Push the button to walk through the operation modes...

Page 4: ...ough the operation modes OFF COOL and HEAT 7 OPERATION lamp This lamp lights up during operation It blinks once to announce that the remote control signal has been received and stored 8 STANDBY lamp T...

Page 5: ...ing this air conditioner If you still have any difficulties or problems consult your dealer for help This air conditioner is designed to give you comfortable room conditions Use this only for its inte...

Page 6: ...cool or heat mode heating The air conditioner makes the room warmer dry The air conditioner reduces the humidity in the room cooling The air conditioner makes the room cooler fan The air conditioner w...

Page 7: ...ton and switch the air condioner ON 3 Press the TEMP buttons to set the desired temperature the temperature range is between 32 C max and 10 C min When this setting is selected the air conditioner cal...

Page 8: ...ng when the sensor on the remote control unit is ON Refer to temperature sensor selector If the sensor on the indoor unit is being used then actual operation will slightly differ from that described i...

Page 9: ...s are displayed The display will change automatically back to show the present time after 10 sec 3 Press the ON OFF button to start the air conditioner 4 Press the TIMER SEL button two times to activa...

Page 10: ...remote control may no longer match If this should happen shut off the unit wait for the flap to close and then turn on the unit again the flap position will now be normal again Do not have the flap po...

Page 11: ...el open all the way grip both arms with your hans and pull toward you to remove To remount hold the front panel roughly horizontal and push it in until the arm shafts fit into the indenta tions in the...

Page 12: ...n 8 Fix again the four screws of the support plates and the frame group aligning the corner from which the wires exit and the corner with the connectors of the unit 9 Mount the air intake grille along...

Page 13: ...bon air filter cannot remove harmful gases or vapors nor ventilate air in the room You must open doors or windows frequently when you use gas or oil heating appliances Otherwise there is a risk of suf...

Page 14: ...n button is OFF 4 Batteries in remote control unit have run down Remedy 1 Restore power 2 Contact service centre 3 Press the button again 4 Replace batteries Trouble Poor cooling or heating performanc...

Page 15: ...e n gatif et enlever le p le positif comme repr sent dans la figure Enlever l autre pile de la m me mani re WIE DIE BATTERIEN ZU ENTFERNEN Die Abdeckung entfernen Drucken Sie die Batterie nach dem neg...

Page 16: ...cubierto por el protocolo de Kyoto con potencial de calentamiento global GWP 1975 N o exale R410A na atmosfera R410A um fluorinated g s coberto pelo protocolo de Kyoto com um global Potencial Aquecen...

Reviews: