background image

13

TIPS FOR ENERGY SAVING

DO NOT:

Block the air intake and outlet of the unit. 
If they are obstructed, the unit will not work well, and
may be damaged.

Let direct sunlight into the room. Use sunshades, 
blind or curtain.

DO:

Always try to keep the air filter clean. A clogged filter 
will impair the performance of the unit.

To prevent conditioned air from escaping, keep windows,
doors and any other openings closed.

FILTER CLEANING

Use a vacuum cleaner to remove light dust. If there is
sticky dust on the filter, wash the filter in lukewarm, soapy
water, rinse it in clean water, and dry it.

1.Remove the screw on each side out of the latch using a

screwdriver.

2.Press on the two latches of the air intake grille with your

thumbs in the direction of the arrow to open the grille.

3.Open the air intake grille downward.

4.Remove the air filter from the air intake grille. Clean the

air filter.

5.Insert the filter correctly again inside the grille, close the

grille letting the latches slide toward the outside and fix
again the latch with the screw on both sides.

SDI MODELS

EG

1.Remove the screw.

2.Remove the filter and clean it.

3.Insert the filter again and fix the screw.

ACTIVATED CARBON AIR FILTER
(ACCESSORY SUPPLIED ON REQUEST -
ONLY FOR FCI MODELS)

This activated carbon air filter cannot remove harmful gases

or vapors nor ventilate air in the room. You must open doors

or windows frequently  when you use gas or oil heating

appliances. Otherwise there is a risk  of suffocation in an

extreme case.

NOTE

1.Two activated carbon air filters for one indoor unit are in

this polyethylene bag.

2.Open the bag just before installing the activated carbon air

filters, if not the  deodorizing effect durability of the filter may
be decreased.

REPLACEMENT OF ACTIVATED CARBON AIR
FILTER

The filter is disposable.

Do not throw away the filter frame.

The used filter cannot be reused even after cleaning up.

Obtain the filters for replacement at your nearest dealer.

Check the state of dirtiness at least once every two
weeks.

Replace the filter after six months’ operation.

WARNING

The activated carbon air filter is to be added to the standard

filter.
It is made of two layers:

- the first layer consists in a synthetic honey comb high

efficiency media to remove the dust and purifing the

air.

- the second layer in charcoal media deodorizing the

ambient air.

ACTIVATED CARBON AIR FILTER INSTALLATION
PROCEDURE
1. 
Open the unit intake air grille and pull out the standard

air filter.

2. Apply on the rear side of the filter the two spings supplied

with the accessory.

3. Fix the activated carbon filter by the springs.

4. Insert the two air filters one over the other and close

the intake grille.

REAR SIDE OF

AIR FILTER

SPRING

ACTIVATED CARBON

FILTER

Summary of Contents for CA8FIA0R5I

Page 1: ...3 01 10 2010 Split air conditioner system Condizionatore d aria split system Climatiseurs split Split klimager t Acondicionador de aire de consola partida sistema split MTA8FIA0R5I MTA8FBI0R5I KPA8FIA...

Page 2: ...product is marked as it satisfies Directives Low voltage no 2006 95 CE Electromagnetic Compatibility no 89 336 EEC 92 31 EEC and 93 68 EEC This declaration will become void in case of misusage and or...

Page 3: ...Remote control receiver This section picks up infrared signals from the remote control unit Transmitter 6 Operation selector without remote control Push the button to walk through the operation modes...

Page 4: ...ough the operation modes OFF COOL and HEAT 7 OPERATION lamp This lamp lights up during operation It blinks once to announce that the remote control signal has been received and stored 8 STANDBY lamp T...

Page 5: ...ing this air conditioner If you still have any difficulties or problems consult your dealer for help This air conditioner is designed to give you comfortable room conditions Use this only for its inte...

Page 6: ...cool or heat mode heating The air conditioner makes the room warmer dry The air conditioner reduces the humidity in the room cooling The air conditioner makes the room cooler fan The air conditioner w...

Page 7: ...ton and switch the air condioner ON 3 Press the TEMP buttons to set the desired temperature the temperature range is between 32 C max and 10 C min When this setting is selected the air conditioner cal...

Page 8: ...ng when the sensor on the remote control unit is ON Refer to temperature sensor selector If the sensor on the indoor unit is being used then actual operation will slightly differ from that described i...

Page 9: ...s are displayed The display will change automatically back to show the present time after 10 sec 3 Press the ON OFF button to start the air conditioner 4 Press the TIMER SEL button two times to activa...

Page 10: ...remote control may no longer match If this should happen shut off the unit wait for the flap to close and then turn on the unit again the flap position will now be normal again Do not have the flap po...

Page 11: ...el open all the way grip both arms with your hans and pull toward you to remove To remount hold the front panel roughly horizontal and push it in until the arm shafts fit into the indenta tions in the...

Page 12: ...n 8 Fix again the four screws of the support plates and the frame group aligning the corner from which the wires exit and the corner with the connectors of the unit 9 Mount the air intake grille along...

Page 13: ...bon air filter cannot remove harmful gases or vapors nor ventilate air in the room You must open doors or windows frequently when you use gas or oil heating appliances Otherwise there is a risk of suf...

Page 14: ...n button is OFF 4 Batteries in remote control unit have run down Remedy 1 Restore power 2 Contact service centre 3 Press the button again 4 Replace batteries Trouble Poor cooling or heating performanc...

Page 15: ...e n gatif et enlever le p le positif comme repr sent dans la figure Enlever l autre pile de la m me mani re WIE DIE BATTERIEN ZU ENTFERNEN Die Abdeckung entfernen Drucken Sie die Batterie nach dem neg...

Page 16: ...cubierto por el protocolo de Kyoto con potencial de calentamiento global GWP 1975 N o exale R410A na atmosfera R410A um fluorinated g s coberto pelo protocolo de Kyoto com um global Potencial Aquecen...