CARE AND CLEANING

Maintenance operations must be carried out by specially
trained personnel.

For safety, be sure to turn the air conditioner off and also
to disconnect the power before cleaning.

Do not pour water on the indoor unit to clean it. This will
damage the internal components and cause an electric
shock hazard.

WARNING

The front panel can be removed in order to wash it with
water.

CASING AND GRILLE (INDOOR UNIT)

Clean the casing and grille of the indoor unit with a vacuum
cleaner brush, or wipe them with a clean, soft cloth.
If these parts are stained, use a clean cloth moistened with
a mild liquid detergent.
When cleaning the grille, be careful not to force the vanes
out of place.

Never use solvents, or harsh chemicals when cleaning the
indoor unit. Do not wipe the plastic casing using very hot
water.

Some metal edges and the vanes are sharp and may
cause injury if handled improperly; be especially careful
when you clean these parts.

The internal coil and other components of the outdoor
unit must be cleaned every year. Consult your dealer or
service centre.

CAUTION

HOW TO REMOVE THE FRONT PANEL (ONLY FOR AWI-
ASI MODELS)

With the front panel open all the way, grip both
arms with your hans and pull toward you to remove.

To remount, hold the front panel roughly horizontal 
and push it in until the arm shafts fit into the indenta-
tions in the main unit, then fit the front panel into place.

Front

panel

2. WHEN THE AIR CONDITIONER IS RUNNING

If you want to turn off the air conditioner push the operation
selector with a pen until the OPERATION lamp is turned off.

Power failure during operation.
In the event of power failure, the unit will stop. When the
power is resumed, the unit will restart automatically after 3
minutes.

NOTE

If you have lost the remote control unit or it has troubles,
follow the steps below.

1. WHEN THE AIR CONDITIONER IS STOPPED
If you want to turn on the air conditioner push the operation
selector with a pen to select the desired mode (COOL or
HEAT).

OPERATION WITHOUT THE REMOTE
CONTROL UNIT

The air conditioner will start in HIGH fan speed. 
The temperature setting is 25°C for cooling mode and
21°C for heating mode.

NOTE

O P E R AT I O N
SELECTOR

FCI MODELS

OPERATION
SELECTOR

ASI MODELS

OPERATION
SELECTOR

AWI MODELS

OPERATION
SELECTOR

SDI MODELS

AWI MODELS

ASI MODELS

GRILLE

STRING

Detach the safety string from the frame (remember to 
attach it again after cleaning or maintenance).

Open the air intake grille, hold it on and pull it toward 

you to detach the two guides.

EG

Summary of Contents for CA8FIA0R5I

Page 1: ...3 01 10 2010 Split air conditioner system Condizionatore d aria split system Climatiseurs split Split klimager t Acondicionador de aire de consola partida sistema split MTA8FIA0R5I MTA8FBI0R5I KPA8FIA...

Page 2: ...product is marked as it satisfies Directives Low voltage no 2006 95 CE Electromagnetic Compatibility no 89 336 EEC 92 31 EEC and 93 68 EEC This declaration will become void in case of misusage and or...

Page 3: ...Remote control receiver This section picks up infrared signals from the remote control unit Transmitter 6 Operation selector without remote control Push the button to walk through the operation modes...

Page 4: ...ough the operation modes OFF COOL and HEAT 7 OPERATION lamp This lamp lights up during operation It blinks once to announce that the remote control signal has been received and stored 8 STANDBY lamp T...

Page 5: ...ing this air conditioner If you still have any difficulties or problems consult your dealer for help This air conditioner is designed to give you comfortable room conditions Use this only for its inte...

Page 6: ...cool or heat mode heating The air conditioner makes the room warmer dry The air conditioner reduces the humidity in the room cooling The air conditioner makes the room cooler fan The air conditioner w...

Page 7: ...ton and switch the air condioner ON 3 Press the TEMP buttons to set the desired temperature the temperature range is between 32 C max and 10 C min When this setting is selected the air conditioner cal...

Page 8: ...ng when the sensor on the remote control unit is ON Refer to temperature sensor selector If the sensor on the indoor unit is being used then actual operation will slightly differ from that described i...

Page 9: ...s are displayed The display will change automatically back to show the present time after 10 sec 3 Press the ON OFF button to start the air conditioner 4 Press the TIMER SEL button two times to activa...

Page 10: ...remote control may no longer match If this should happen shut off the unit wait for the flap to close and then turn on the unit again the flap position will now be normal again Do not have the flap po...

Page 11: ...el open all the way grip both arms with your hans and pull toward you to remove To remount hold the front panel roughly horizontal and push it in until the arm shafts fit into the indenta tions in the...

Page 12: ...n 8 Fix again the four screws of the support plates and the frame group aligning the corner from which the wires exit and the corner with the connectors of the unit 9 Mount the air intake grille along...

Page 13: ...bon air filter cannot remove harmful gases or vapors nor ventilate air in the room You must open doors or windows frequently when you use gas or oil heating appliances Otherwise there is a risk of suf...

Page 14: ...n button is OFF 4 Batteries in remote control unit have run down Remedy 1 Restore power 2 Contact service centre 3 Press the button again 4 Replace batteries Trouble Poor cooling or heating performanc...

Page 15: ...e n gatif et enlever le p le positif comme repr sent dans la figure Enlever l autre pile de la m me mani re WIE DIE BATTERIEN ZU ENTFERNEN Die Abdeckung entfernen Drucken Sie die Batterie nach dem neg...

Page 16: ...cubierto por el protocolo de Kyoto con potencial de calentamiento global GWP 1975 N o exale R410A na atmosfera R410A um fluorinated g s coberto pelo protocolo de Kyoto com um global Potencial Aquecen...

Reviews: