background image

The following symbols used in this manual, alert you to

potentially dangerous conditions to users, service personnel

or the appliance:

This symbol refers to a hazard or unsafe practice which

can result in severe personal injury or death.

This symbol refers to a hazard or unsafe practice which

can result in personal injury or product or property damage.

This air conditioner is equipped with cooling, drying, heating and fan only functions. 
Details on these functions are provided below; refer on these descriptions when using the air conditioner.

CONTENTS

2

NAME OF PARTS AND OPERATION SELECTOR SWITCH

3

INSTALLATION LOCATION

5

ELECTRICAL REQUIREMENTS

5

SAFETY INSTRUCTIONS

5

USING THE REMOTE CONTROL UNIT

5

REMOTE CONTROL UNIT

6

HOW TO SET THE PRESENT TIME

7

COOLING

7

HEATING

7

AUTOMATIC OPERATION

7

DEHUMIDIFYING (DRY)

7

FAN ONLY

8

ADJUSTING THE FAN SPEED 

8

FILTER Ti0

2

8

NIGHT MODE/ENERGY SAVING

8

HIGH POWER MODE

8

SETTING THE TIMER 

9

SETTING THE 1 HOUR TIMER 

9

ADJUSTING THE AIR FLOW DIRECTION 

9

OPERATION WITHOUT THE REMOTE CONTROL UNIT

11

CARE AND CLEANING

11

TIPS FOR ENERGY SAVING

13

TROUBLESHOOTING

14

DECLARATION OF CONFORMITY

This product is marked            as it satisfies Directives:
– Low voltage no. 2006/95/CE.
– Electromagnetic Compatibility no. 89/336 EEC, 92/31 EEC and 93/68 EEC. 
This declaration will become void in case of misusage and/or from non observance though partial of Manufacturer's
installation and/or operating instructions.

NOTE

PRODUCT INFORMATION

If you have problems or questions concerning your Air
Conditioner, you will need the following information. Model
and serial numbers are on the nameplate on the bottom of
the cabinet.
Model No.
Serial No.
Date of purchase
Dealer’s address
Phone number

ALERT SYMBOLS

EG

WARNING

CAUTION

INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH THE EUROPEAN
DIRECTIVE 2002/96/EC

At the end of its working life this equipment must not be disposed of as an household waste.
It must be taken to special local community waste collection centres or to a dealer providing this service.
Disposing of an electrical and electronic equipment and its batteries separately avoids possible negative effects on the
environment and human health deriving from an inappropriate disposal and enables its components to be recovered
and recycled to obtain significant savings in energy and resources. 
In order to underline the duty to dispose of this equipment and batteries separately, the product is marked with a
crossed-out dustbin.

Summary of Contents for CA8FIA0R5I

Page 1: ...3 01 10 2010 Split air conditioner system Condizionatore d aria split system Climatiseurs split Split klimager t Acondicionador de aire de consola partida sistema split MTA8FIA0R5I MTA8FBI0R5I KPA8FIA...

Page 2: ...product is marked as it satisfies Directives Low voltage no 2006 95 CE Electromagnetic Compatibility no 89 336 EEC 92 31 EEC and 93 68 EEC This declaration will become void in case of misusage and or...

Page 3: ...Remote control receiver This section picks up infrared signals from the remote control unit Transmitter 6 Operation selector without remote control Push the button to walk through the operation modes...

Page 4: ...ough the operation modes OFF COOL and HEAT 7 OPERATION lamp This lamp lights up during operation It blinks once to announce that the remote control signal has been received and stored 8 STANDBY lamp T...

Page 5: ...ing this air conditioner If you still have any difficulties or problems consult your dealer for help This air conditioner is designed to give you comfortable room conditions Use this only for its inte...

Page 6: ...cool or heat mode heating The air conditioner makes the room warmer dry The air conditioner reduces the humidity in the room cooling The air conditioner makes the room cooler fan The air conditioner w...

Page 7: ...ton and switch the air condioner ON 3 Press the TEMP buttons to set the desired temperature the temperature range is between 32 C max and 10 C min When this setting is selected the air conditioner cal...

Page 8: ...ng when the sensor on the remote control unit is ON Refer to temperature sensor selector If the sensor on the indoor unit is being used then actual operation will slightly differ from that described i...

Page 9: ...s are displayed The display will change automatically back to show the present time after 10 sec 3 Press the ON OFF button to start the air conditioner 4 Press the TIMER SEL button two times to activa...

Page 10: ...remote control may no longer match If this should happen shut off the unit wait for the flap to close and then turn on the unit again the flap position will now be normal again Do not have the flap po...

Page 11: ...el open all the way grip both arms with your hans and pull toward you to remove To remount hold the front panel roughly horizontal and push it in until the arm shafts fit into the indenta tions in the...

Page 12: ...n 8 Fix again the four screws of the support plates and the frame group aligning the corner from which the wires exit and the corner with the connectors of the unit 9 Mount the air intake grille along...

Page 13: ...bon air filter cannot remove harmful gases or vapors nor ventilate air in the room You must open doors or windows frequently when you use gas or oil heating appliances Otherwise there is a risk of suf...

Page 14: ...n button is OFF 4 Batteries in remote control unit have run down Remedy 1 Restore power 2 Contact service centre 3 Press the button again 4 Replace batteries Trouble Poor cooling or heating performanc...

Page 15: ...e n gatif et enlever le p le positif comme repr sent dans la figure Enlever l autre pile de la m me mani re WIE DIE BATTERIEN ZU ENTFERNEN Die Abdeckung entfernen Drucken Sie die Batterie nach dem neg...

Page 16: ...cubierto por el protocolo de Kyoto con potencial de calentamiento global GWP 1975 N o exale R410A na atmosfera R410A um fluorinated g s coberto pelo protocolo de Kyoto com um global Potencial Aquecen...

Reviews: