Maintenance  

Make sure fixture is cool and disconnected from power mains before any service. 

 

 

 
Weekly operating hours and environmental conditions will establish how often the fixtures need 
cleaning.  Fixtures should be cleaned and inspected at least once a month to maintain optimum 
performance.  Accumulation of dust and fog residue increases heat build up, can lead to 
malfunctions, overheating and reduction in maximum light output.  This condition may cause 
undue stress on electronics, mechanical elements, reduce LED Engine life, fixture life and over 
all performance.  Before conducting any maintenance, disconnect fixture from power mains.   
  
1) Disconnect fixture from power mains. 
2) Use a vacuum with a soft brush to remove dust collected on external vents and internal 
components.  If using an air compressor, use low pressures and extreme care to prevent 
damaging any internal parts or effects. 
3) Vacuum dust buildup from fan intakes and check that all fans function correctly. 
4) Clean all optical elements when the fixture is cold.  Use a soft lint free cotton cloth or tissue 
and either Isopropyl or Denatured Alcohol.  Any cleaner approved for coated eyeglass lenses 
will also work.  
5) Inspect clamps and safety cables to ensure fixture is secure and safe. 

Summary of Contents for VectorLED 160 Spot

Page 1: ...V Ve ec ct to or rL LE ED D 1 16 60 0 S Sp po ot t Information specifically for DM VectorLED160S V1 0 This manual contains important information Please read before operating fixture...

Page 2: ...2 2010 Techni Lux Inc...

Page 3: ...ceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux directl...

Page 4: ...Panel Menu 11 DMX 512 Start Address 12 DMX 512 Channel Assignment 12 CH 1 Shutter Strobe Reset 13 CH 2 Dimmer 13 CH 3 Color Wheel 13 CH 4 Rotating Gobo Wheel 14 CH 5 Gobo Rotation and Index 14 CH 6 Fo...

Page 5: ...prism variable speed in both directions Beam angle 11 Motorized focus Digital shutter for 0 20 FPS strobing effects and quick blackouts Digital dimming 0 100 for smooth fades and even fields DMX512 Co...

Page 6: ...0 240v 50 or 60Hz Connection IEC C13 Power Inlet with Fuse Rated Power 170W 1 5A 115v Fuses 5A Fast Blow Size 5x20mm Control Protocol USITT DMX512 1990 Channels 12 Pan Tilt Resolution 16 bit Data I O...

Page 7: ...7 Unit Parts 1 Head 2 Yoke 3 Base 4 Control Panel 5 Base Bottom 6 Omega Clamp Adapter...

Page 8: ...plied to return items not received in original or incomplete packing Claims Physical damage must be reported to the Freight Carrier or Shipping Company upon receipt of merchandise Damage incurred in s...

Page 9: ...r normal conditions All fixtures must be powered directly from a switched circuit This fixture cannot be run on rheostat or dimmer circuits even if used solely for a 0 to 100 switching Consult a quali...

Page 10: ...ted in any position provided there is adequate room for movement and ventilation Mount the fixture securely using an appropriate clamp and a safety cable Safety cables must always be attached to the f...

Page 11: ...ON Inverted Tilt 100 to 0 PAtI T InU OFF Normal Tilt 0 to 100 NorM Default Pan Tilt Speed FAST Maximum Pan Tilt Speed Ptsp Slow Slow Pan Tilt Speed ON Display Remains On TURN Display Inverted dISP 1O...

Page 12: ...ixtures will be slaved together and respond to the same data Example Select Start Addresses for 4 fixtures each requiring 12 channels of DMX Since these are the first fixtures added to the system the...

Page 13: ...sed to vary the intensity of the beam from full open to dark This channel also works directly on the LED Light Engine Electronic control makes for smooth dimming while maintaining an absolutely flat f...

Page 14: ...obo 4 Metal 80 95 Rotating Gobo 5 Metal 96 111 Rotating Gobo 6 Glass 112 127 Rotating Gobo 7 Metal 128 191 Rotating Gobo Scroll Fast to Slow CCW 192 255 Rotating Gobo Scroll Slow to Fast CW CH 5 Gobo...

Page 15: ...Pan and Tilt Speed and Movement options are controlled by the Pan Tilt Speed Auto Sound Channel 12 CH 8 Pan Coarse Position 540 CH 9 Pan Fine Position 3 6 CH 10 Tilt Coarse Position 270 CH 11 Tilt Fin...

Page 16: ...s handled by the controller The physical signals are transmitted using a twisted pair of wires and a common shield a configuration called Balanced The controller and all receiving equipment are connec...

Page 17: ...then connect pin 2 to pin 2 and pin 3 to pin 3 This is true for converting either 5 to 3 pin or 3 to 5 pin regardless of either connector s gender Pins 4 and 5 are not used on the 5 pin XLR connector...

Page 18: ...life fixture life and over all performance Before conducting any maintenance disconnect fixture from power mains 1 Disconnect fixture from power mains 2 Use a vacuum with a soft brush to remove dust c...

Page 19: ...programming Check that both Shutter and Dimmer values are set properly Inspect fixture light path and verify no effects are blocking beam Remove from DMX Control Panel to test in demo manual mode Ove...

Page 20: ...3 pin XLR Cable CA XLR3 50 Pre made 50 3 pin XLR Cable CA XLR3 100 Pre made 100 3 pin XLR Cable CA XLR5 1 Pre made 1 5 pin XLR Cable CA XLR5 5 Pre made 5 5 pin XLR Cable CA XLR5 10 Pre made 10 5 pin X...

Reviews: