background image

 

3

IMPORTANT INFORMATION

 

 
 

Save original packing and documentation for warranty, service and return issues

 
 
Limited Warranty: This warranty covers defects or malfunctions in this equipment.  This warranty lasts for 
a period of one year from date of purchase.  It is the owner’s responsibility to provide invoices for proof of 
purchase, purchase date and dealer or distributor.  If purchase date can not be provided, warranty period 
will start at manufacture date.  It is the sole discretion of Techni-Lux to repair or replace parts or 
equipment.   All shipping will be paid by purchaser.  This warranty does not cover lamps, fuses, belts, 
power semiconductors, relays, cleaning, standard maintenance adjustments or normal wear items or any 
problem resulting from the following: improper wiring, incorrect voltage (including low or over voltage 
conditions and lightning), abuse, misuse, improper maintenance or an act of God or damage resulting 
from shipping.  Warranty will be null and void if the product is altered, modified, misused, damaged, or 
subjected to unauthorized repairs.  Lamps are covered by relevant manufacturer warranty. This warranty 
gives you specific legal rights, and you may also have other rights which vary from state to state.  Any 
liability for consequential and incidental damages is expressly disclaimed.  No other warranty, expressed 
or implied is made.  Techni-Lux liability in all events is limited to, and shall not exceed, the purchase 
price paid. 
 
Returning equipment and Repairs:  All returns must be accompanied by a Return Merchandise 
Authorization (RMA) number and sent pre-paid.  Contact the dealer or Techni-Lux directly to obtain an 
RMA.  The RMA number must be clearly listed on the shipping label.  Due care must be exercised in 
packing all merchandise to be returned.  All repairs must be accompanied by a written explanation of the 
claimed problem or error encountered.  Techni-Lux is solely responsible for determining a product’s 
eligibility for coverage under warranty.  If returning for consideration of credit, all accessories and 
documentation, original protective material and cartons must be included and the equipment, packing 
and carton must be in new resalable condition. Credit for returned merchandise will be issued at the 
lowest current price and is subject to a restocking fee.  No returns accepted on discontinued items.  
Techni-Lux is not responsible for merchandise damaged in transit and reserves the right to refuse any 
return that is damaged by the carrier, not accompanied by a Return Authorization Number (RMA#) or 
sent by freight collect.   
 
Claims:  All claims must be made within seven (7) days of receipt of merchandise.  Any physical damage 
must be reported to carrier upon receipt of merchandise. 
 
 

Please record the following information for future reference: 

Model Number: DM-VectorLED160S 

 

Serial Number: ________________________________________ 

 

Dealer: ______________________________________________ 

 

Date of Purchase: ______________________________________ 

 

www.Techni-Lux.com 
10900 Palmbay Drive 

Orlando, FL 32824 

U.S.A. 

Summary of Contents for VectorLED 160 Spot

Page 1: ...V Ve ec ct to or rL LE ED D 1 16 60 0 S Sp po ot t Information specifically for DM VectorLED160S V1 0 This manual contains important information Please read before operating fixture...

Page 2: ...2 2010 Techni Lux Inc...

Page 3: ...ceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux directl...

Page 4: ...Panel Menu 11 DMX 512 Start Address 12 DMX 512 Channel Assignment 12 CH 1 Shutter Strobe Reset 13 CH 2 Dimmer 13 CH 3 Color Wheel 13 CH 4 Rotating Gobo Wheel 14 CH 5 Gobo Rotation and Index 14 CH 6 Fo...

Page 5: ...prism variable speed in both directions Beam angle 11 Motorized focus Digital shutter for 0 20 FPS strobing effects and quick blackouts Digital dimming 0 100 for smooth fades and even fields DMX512 Co...

Page 6: ...0 240v 50 or 60Hz Connection IEC C13 Power Inlet with Fuse Rated Power 170W 1 5A 115v Fuses 5A Fast Blow Size 5x20mm Control Protocol USITT DMX512 1990 Channels 12 Pan Tilt Resolution 16 bit Data I O...

Page 7: ...7 Unit Parts 1 Head 2 Yoke 3 Base 4 Control Panel 5 Base Bottom 6 Omega Clamp Adapter...

Page 8: ...plied to return items not received in original or incomplete packing Claims Physical damage must be reported to the Freight Carrier or Shipping Company upon receipt of merchandise Damage incurred in s...

Page 9: ...r normal conditions All fixtures must be powered directly from a switched circuit This fixture cannot be run on rheostat or dimmer circuits even if used solely for a 0 to 100 switching Consult a quali...

Page 10: ...ted in any position provided there is adequate room for movement and ventilation Mount the fixture securely using an appropriate clamp and a safety cable Safety cables must always be attached to the f...

Page 11: ...ON Inverted Tilt 100 to 0 PAtI T InU OFF Normal Tilt 0 to 100 NorM Default Pan Tilt Speed FAST Maximum Pan Tilt Speed Ptsp Slow Slow Pan Tilt Speed ON Display Remains On TURN Display Inverted dISP 1O...

Page 12: ...ixtures will be slaved together and respond to the same data Example Select Start Addresses for 4 fixtures each requiring 12 channels of DMX Since these are the first fixtures added to the system the...

Page 13: ...sed to vary the intensity of the beam from full open to dark This channel also works directly on the LED Light Engine Electronic control makes for smooth dimming while maintaining an absolutely flat f...

Page 14: ...obo 4 Metal 80 95 Rotating Gobo 5 Metal 96 111 Rotating Gobo 6 Glass 112 127 Rotating Gobo 7 Metal 128 191 Rotating Gobo Scroll Fast to Slow CCW 192 255 Rotating Gobo Scroll Slow to Fast CW CH 5 Gobo...

Page 15: ...Pan and Tilt Speed and Movement options are controlled by the Pan Tilt Speed Auto Sound Channel 12 CH 8 Pan Coarse Position 540 CH 9 Pan Fine Position 3 6 CH 10 Tilt Coarse Position 270 CH 11 Tilt Fin...

Page 16: ...s handled by the controller The physical signals are transmitted using a twisted pair of wires and a common shield a configuration called Balanced The controller and all receiving equipment are connec...

Page 17: ...then connect pin 2 to pin 2 and pin 3 to pin 3 This is true for converting either 5 to 3 pin or 3 to 5 pin regardless of either connector s gender Pins 4 and 5 are not used on the 5 pin XLR connector...

Page 18: ...life fixture life and over all performance Before conducting any maintenance disconnect fixture from power mains 1 Disconnect fixture from power mains 2 Use a vacuum with a soft brush to remove dust c...

Page 19: ...programming Check that both Shutter and Dimmer values are set properly Inspect fixture light path and verify no effects are blocking beam Remove from DMX Control Panel to test in demo manual mode Ove...

Page 20: ...3 pin XLR Cable CA XLR3 50 Pre made 50 3 pin XLR Cable CA XLR3 100 Pre made 100 3 pin XLR Cable CA XLR5 1 Pre made 1 5 pin XLR Cable CA XLR5 5 Pre made 5 5 pin XLR Cable CA XLR5 10 Pre made 10 5 pin X...