5)  Alarm ID with flag. 

 
To deactivate any alert, please set its value to “0”. 
 
Alerts are reported as follows: 

 

In software, by system bus (alerts 1, 2, 3, 4, 5) 

 

Acoustic (alerts 1, 2, 3, 4) 

 

Activating the alert output (alerts 1, 2, 3, 5) 

 
The alarm message via the communication line assumes an online connected PC with the appropriate software suitable 
for online operation (APS Administrator). 
 
The audible alert message is twofold: 

 

Continuous tone (distortion) 

 

Intermittent tone (knocked out and long open door, APB alarm) 

 
The acoustic message ends either after the set time (see configuration table) 
or after reading a valid ID on the relevant module. 
 
When one of the relevant used alarm conditions occurs (signaling time 
alarm must be greater than 0) the alarm output will be activated. On this output is 
it is possible to connect the alarm device directly or to further process its signal. 
 
The triggering of the alarm is controlled by a logical connection or between individual types 
alarms. 
 
The alarm condition is terminated by restoring all idle conditions (closing the door, fitting the cover, etc.). 
 

7.8.1  Tamper 

The MREM 82 NO/IGBKP reader module is not equipped with a Tamper sensor to detect that the lid is open. 
 

7.8.2  Forced door 

The "Forced door" status occurs when the IN1 input of the module is opened without first activating the "Door open" 
function. The only exception is the exit button / handle contact signal activation from the inner side of the door. 
 

7.8.3  Door ajar 

The "Dopr ajar" status is activated by opening the door for a longer time than allowed (set), see the configuration table. 
 

7.8.4  Antipassback alarm 

Antipassback alarm is generated when a valid card is read at the time of blocking the user by Time APB, 
or when the user is blocked by a Zone APB. 
 

7.8.5  Alarm ID with flag 

Alarm ID with a flag occurs when a card (ID) with  flag is read. 
 

7.8.6  Reading ID in time of alert 

Reading a valid ID has no effect on the alarm conditions themselves. It is terminated with a valid ID 
only an audible alarm, followed by the "door open" function. Reading an invalid ID only interrupts the audible alarm for the 
duration of the "invalid ID" signaling. 
 

 

Summary of Contents for 534821E2

Page 1: ...MREM 82 NOGBKP RFID module 13 56 MHz 125 kHz...

Page 2: ...Reading id media MIFARE NFC EM Marin Jablotron 1x RS 485 system bus APS mini Plus 1x Wiegand external RFID reader GSM module license plate camera or next RS 485 OEM 1x Open drain transistor output 60...

Page 3: ...egand input system bus power supply The reader module can operate autonomously or as a part of the system Connection on the RS 485 bus with control from a mobile phone from the WebHit cloud applicatio...

Page 4: ...HW address setting 13 5 3 Meaning of LED indicators 14 5 4 Configurable parameters 15 6 Operating modes 16 6 1 Standard operating mode 16 6 2 External reader with Wiegand output 17 7 Function 18 7 1 F...

Page 5: ...emory ID media Events Time plans 2000 3400 64 pc Signalization RGB led Piezo 1 1 pc 1 2 Communication interface INTERFACE DESCRIPTION TECHNOLOGY PROPERTIES System data bus RS 485 19 200 bit s 8 data b...

Page 6: ...ion Door contact 9 White Signal B system data bus APS mini Plus system bus 10 Black Signal A system data bus APS mini Plus system bus 2 1 1 Inputs and Outputs INPUT OUTPUT DESCRIPTION Input 1 IN 1 Doo...

Page 7: ...bstrates it is recommended to perform a practical reading test or contact support techfass cz Interference along the line e g from an interfering power supply can affect the reading distance or the re...

Page 8: ...g the cabling on the surface it is possible to use a surface installation box which will allow you to pull the cable of the reading module over the wall surface First mount the installation box to the...

Page 9: ...bit CSN 56 bit CSN TF Mobile ID Disabled Disabled Disabled 32 data bits MSB 32 data bits MSB 32 data bits MSB 32 data bits reversed LSB 32 data bits reversed LSB 32 data bits reversed LSB 24 data bits...

Page 10: ...ile ID read format and length setting options are shown in the image above print screen from APS Reader 3 2 Reading at 125 kHz The EM or dual variant of the device can also read media with a frequency...

Page 11: ...as its own memory of events users real time clock controls the lock reads inputs for door contact or exit button and is able to report alarms such as knocked out door or door ajar USECASE B System wis...

Page 12: ...to the reader module The module with the wiegand output the one that does not control the lock is located on the outside if it is an entrance door A minimum of 4 wires are required to connect it for...

Page 13: ...rodukty 101 produkt 1355 aps hit The desktop application for administration Small medium installation APS Hit https www techfass com cs produkty 101 produkt 1355 aps hit Medium large APS Administrator...

Page 14: ...needed hw address 5 3 Meaning of LED indicators COLOR ACTION DESCRIPTION Red Continuously lit Online communication of the RS 485 system bus Flashing with a period of 4 s Offline operation Green Flash...

Page 15: ...5 s 0 s Forced door alert signalization time 0 255 s 0 s Door ajar alert signalization time 0 255 s 0 s Door ajar allowed opened door time 0 255 s 20 s ID with Alarm flag alert signalization time 0 25...

Page 16: ...ds 6 1 2 Online mode In Online mode the module or more modules on the line are connected to a PC running the relevant application such as APS Hit or APS Administrator or the line is connected to the c...

Page 17: ...Default settings 40 bits format Wiegand output setting 125 kHz bits Data length 26 32 42 44 56 Default settings 42 bits format 6 2 2 13 56 MHz 32 bit CSN 56 bit CSN TF Mobile ID Disable Disable Disab...

Page 18: ...elay output remains unchanged until the next activation of the Door open function In the case of the pulse lock control mode after activating the Door open function the relay output is activated for t...

Page 19: ...address Enable door opening after time APB alarm if the function is enabled the Door opening function is started in case of time APB alarm 7 6 2 Zone antipassback Zone antipassback is defined by enab...

Page 20: ...r between individual types alarms The alarm condition is terminated by restoring all idle conditions closing the door fitting the cover etc 7 8 1 Tamper The MREM 82 NO IGBKP reader module is not equip...

Page 21: ...pair of programming cards and cards It does not enter the programming mode while waiting for the card confirming the address setting for modules with address setting via the communication line The beh...

Page 22: ...goes back into standard operating mode Deleting cards 7 10 3 Deleting cards above or below If a user loses his ID medium it is usually impossible to delete the ID from the memory with the procedure d...

Page 23: ...ing all cards 7 10 5 Recommended method for access rights management using prog cards In case of managing access rights of plenty of users using programming cards only it is appropriate to establish a...

Page 24: ...ocedure from chapter 6 7 1 again 1 Read inserting programming card read cards 1 5 after 15 s the programming mode is exited Register the change in your table Table after inserting card 6 A new card is...

Page 25: ...ACH 8 2 Declaration of conformity The manufacturer TECH FASS ltd declares that the product follows legal requirements and fulfils necessary European directives The declaration of conformity document c...

Page 26: ...TECH FASS s r o V t nsk 1611 19 Praha...

Reviews: