5) Alarm ID with flag.
To deactivate any alert, please set its value to “0”.
Alerts are reported as follows:
▪
In software, by system bus (alerts 1, 2, 3, 4, 5)
▪
Acoustic (alerts 1, 2, 3, 4)
▪
Activating the alert output (alerts 1, 2, 3, 5)
The alarm message via the communication line assumes an online connected PC with the appropriate software suitable
for online operation (APS Administrator).
The audible alert message is twofold:
▪
Continuous tone (distortion)
▪
Intermittent tone (knocked out and long open door, APB alarm)
The acoustic message ends either after the set time (see configuration table)
or after reading a valid ID on the relevant module.
When one of the relevant used alarm conditions occurs (signaling time
alarm must be greater than 0) the alarm output will be activated. On this output is
it is possible to connect the alarm device directly or to further process its signal.
The triggering of the alarm is controlled by a logical connection or between individual types
alarms.
The alarm condition is terminated by restoring all idle conditions (closing the door, fitting the cover, etc.).
7.8.1 Tamper
The MREM 82 NO/IGBKP reader module is not equipped with a Tamper sensor to detect that the lid is open.
7.8.2 Forced door
The "Forced door" status occurs when the IN1 input of the module is opened without first activating the "Door open"
function. The only exception is the exit button / handle contact signal activation from the inner side of the door.
7.8.3 Door ajar
The "Dopr ajar" status is activated by opening the door for a longer time than allowed (set), see the configuration table.
7.8.4 Antipassback alarm
Antipassback alarm is generated when a valid card is read at the time of blocking the user by Time APB,
or when the user is blocked by a Zone APB.
7.8.5 Alarm ID with flag
Alarm ID with a flag occurs when a card (ID) with flag is read.
7.8.6 Reading ID in time of alert
Reading a valid ID has no effect on the alarm conditions themselves. It is terminated with a valid ID
only an audible alarm, followed by the "door open" function. Reading an invalid ID only interrupts the audible alarm for the
duration of the "invalid ID" signaling.