TS580D-MM
Micro-Meter Mix Controller USER GUIDE
5
Operation
5.1 Connecting the Unit
1.
Connect the power cord and foot switch to the back of the unit.
2.
Connect the pumps to Ports C and D. The Left pump is typically connected to
Port C and the Right pump is typically connected to Port D.
3.
Connect Syringe air hoses to Ports A and B.
Caution
: Port A and B share the same regulated air source. If the viscosity of the resin
is significantly higher than the hardener, please use an external regulated air source for
the resin.
4.
Press the Power switch to turn on the unit.
5.1.1 Login
1.
From the Home screen, touch the Login icon to enter the Login screen.
2.
Enter “0000” in the Password window (Password
window should be highlighted
with a green box).
3.
Touch green check
to accept.
4.
Optionally check
“
Password Disabled
”
- no further login will be required.
5.
Touch the Home screen button
to return to the Home screen.
Figure 3