10
If constant air pressure is required, connect syringe air hose to accessory
air outlet port located in the rear of the unit, port #13 in figure 1.0
4.
Press the Power button (1) to turn on the unit.
5.
Press the Mode (2) and Set up button (3) simultaneously until “PUMP-E”
appears on the top right hand corner of the Display.
Figure 8.0
5.4.2
Program Selection:
Follow steps in Section 5.3.2
5.4.3
Manual/Purge Dispense Cycle:
Follow steps in Section 5.3.3
5.4.4
Automatic Dispense Cycle Setting:
Follow steps in Section 5.3.4
5.4.5
Iteration for Encoder Count Setting
The maximum default encoder count is 60,000P. However there is an
ITERATION “Itr” feature that can be used to increase the dispense
duration up to 4 times (240,000 counts) without interruption.
1.
Press and hold the Setup button (#3) for 2 seconds to enter setup screen
2.
Press both Power button (#1) and Mode button (#2) simultaneously (3
times) until “Itr” appear.
3.
Press both the Setup button (#3) and (+) button simultaneously to
increase iteration.
4.
Press both the Setup button (#3) and (-) button simultaneously to
decrease iteration
5.
Press the Setup button (#3) to save data and return to main screen.
5.5
CYCLE COUNTER (
Refer to Figure 9.0)
The cycle counter records the numbers of automatic dispense cycle being
activated. Up to 60,000 cycles can be recorded. To reset the counter, follow
steps below:
1.
Press and hold Set button (3) for two seconds to enter setup screen.
2.
Press and hold both Set button (3) and Mode button (2) simultaneously to
clear the counter.
3.
Press and hold Set button (3) for two seconds to exit setup screen.
Figure 9.0
1P 15 PSI
P1 TIMED MODE PUMP-E
20.000V 1
Control Type
Encoder Count
Reverse
Encoder Count
Input Voltage
Program #
Cycle Mode
Pressure Port B
Regulated
Counter
10000P 15 PSI
Pressure Port A (not use)
11
5.6
TO CHANGE PRESSURE UNIT DISPLAY (
Refer to Figure 9.0)
The default pressure unit display is “psi”. To change pressure unit display
to
“bar” follow steps below:
1.
Press and hold Set button (3) for two seconds to enter setup screen.
2.
Press both (+) and (-) button simultaneously two times. The unit “psi” will be
flashing.
3.
Press both Set button (3) and (+) button simultaneously to change unit display
to “bar”. Repeat this step to change unit display back to “psi”
4.
Press and hold Set button (3) for two seconds to exit setup screen.
5.7
LOW PRESSURE SETTING (
Refer to Figure 9.0)
The low-pressure setting is pre-set at the factory to 70 Psi (4.8 bars). When the
supplied pressure drops below 70 Psi (4.8 bars) the unit will not function. To
change the low pressure set point, follow steps below:
1.
Set the dispense cycle in “TIMED MODE” mode.
2.
Press and hold the Set button (3) for two seconds to enter the setup screen.
3.
Press (+) and (-) button simultaneously, the low pressure set point will
appear on display as shown on figure 6.0.
4.
Press the Set button (3) and (+) button simultaneously to increase the set
point.
5.
Press the Set button (3) and (-) button simultaneously to decrease the set
point.
6.
Press and hold the Set button (3) for two seconds to save the data.
Figure 10.0
5.8
MULTIPLE SHOTS SETTING
Up to ten individual or sequential shots can be stored in the TS500R.
Sequential mode is activated in numerical order.
1.
Follow steps in sections “5.1.2 Program Selection” & “5.1.4 Automatic
Dispense Cycle Setting” to set dispense time in desired programs
2.
Press and hold the Mode button (#2) for 2 seconds to turn on sequential
mode
3.
Press and release the Set button (#3) to enter the sequential program setup
mode
4.
Press the (+) or (-) button to set the number of programs to be dispensed
5.
Press and release the Set button (#3) to save selected sequential shot
program
6.
Depress Foot switch to activate sequential dispensed cycle
7.
Press the Mode button (#2) for 2 seconds to exit sequential mode
DISP: 0.100 70 psi
Low pressure
set point
P1 TIMED MODE VALVE