FEATURES
Figure 1.0
5.
SETUP INSTRUCTIONS
5.1
TO CONTROL PNEUMATIC VALVE
CAUTION: A 5-micron filter (TSD800-6) must be installed with the unit to ensure
proper air filtration.
Figure 2.0
Items Description
Items Description
1
Power Button
8
Motor Drive Outlet
2
Mode Button
9
Foot Switch Receptacle
3
Set up/Save Button
10
Power Receptacle
4 Display
11
I/O
Connection
5
Air Outlet (Unregulated)
12
Air Inlet
6
Air Pressure Regulator
13
Accessory Air Outlet
7
Air Outlet (Regulated)
TO AIR SOURCE
10
8
9
5
7
1
2
3
6
4
5
5.1.1
Connecting The Unit:
(Refer to Figure 2.0)
1.
Connect the power cord, foot switch and air hose to the back of the unit.
Make sure the air inlet pressure is 70 psi (4.8 bar) or higher.
2.
Press the Power button (1) to turn on the unit.
3.
Connect Valve air hose to Port A.
NOTE: Pressure in Port A can be monitored by the low pressure setting
but is not regulated by the air regulator in the unit. It delivers the same
pressure as the inlet pressure. On the other hand, pressure in Port B is
regulated but it is not linked to the low pressure setting.
4.
Press the Mode (2) and Set button (3) simultaneously until “VALVE”
appears on the top right hand corner of the Display as shown in Figure 3.0
Figure 3.0
5.1.2
Program selection
1.
Press the Set button (3) to highlight the program number selection.
2.
Press the (+) or (-) buttons to select desired program.
3.
Press the Set button (3) to exit.
5.1.3
Manual/Purge Dispense Cycle Setting:
1.
Press the Mode button (2) until “PURGE” appears on the Display.
2.
Press and hold the Foot Switch to activate dispense cycle.
5.1.4
Automatic Dispense Cycle Setting:
1.
Push the Mode button (2) to select “TIMED MODE” or “INTERRUPT”.
2.
Press and hold the Set button (3) for two seconds to enter set up screen.
The last digit of the dispense time will be highlighted.
3.
Press the Set button (3) to move the cursor to the next position.
4.
Press the (+) or (-) button to set the time
5.
Press and hold the Set button (3) for two seconds to save the data.
6.
If the unit is in “TIMED MODE” mode, press and release the Foot Switch
to activate the timed dispense cycle.
7.
If the unit is in “INTERRUPT”, press and hold the Foot Switch until the
dispense cycle is completed. The dispense cycle can be disrupted if the
Foot Switch is released and resumed when the Foot Switch is depressed
again.
Items Description
Items Description
1
Power Button
6
Air pressure regulator knob
2 Mode
Button 7 Footswitch
3
Set Button
8
Pneumatic Valve (not included)
4
LCD Display
9
Fluid Reservoir (not included)
5
Power Adapter
10
Air Filter
Cycle Mode
Dispense
Time
Program #
Valve Pressure Port
Pressure Port B
Regulated
Counter
Control Type
1
0.100S A: 70 PSI
B: 70 PSI
P1 TIMED MODE VALVE