2. INSTALLATION PROCEDURE
EO18-13004
2.2 Connecting the Drawer
2- 3
2.2 Connecting the Drawer
Connectable drawers must meet the following conditions.
•
The drawer which includes the Drawer Drive Circuit (DC 24V specification).
•
The drawer which has 6-pin modular connector.
Pin Signal
1 FG
2 DRAWER1
3 DRSW
4 VDR
5 DRAWER2
6 GND
1. Turn the printer power OFF.
2. Connect the drawer cable to the drawer interface connector in the correct orientation.
3. Secure the ground wire of the drawer to the ground terminal on the rear of the printer.
WARNING!
1. The solenoid included in the drawer to be connected should have the minimum of 36 ohm
resistance. Under-specified solenoid may cause a machine failure.
2. The output current of the drawer should not exceed 0.8A, as there is a risk of a machine
failure.
3. The drawer interface connector is exclusively for connecting a drawer. Do not connect a
phone line or any other cables than the specified drawer cable. Doing so may cause a failure
of the phone line and the printer.
4. The drawers which are provided with TOSHIBA TEC standard drawer interface (4-pin
modular type connector) cannot be connected to this printer.
6
1
Fig. 2-4
Ground Wire
Ground Terminal
Drawer Interface Connector
Drawer Cable