Programming examples

Example 1

Objective:

 You would like to change the factory settings of the Alarm: 

set output No� 2 Engine locking to control the normally open relay�

Execution:

◊ 

Turn the ignition on�

◊ 

Enter the PIN code and wait for confirmation�

◊ 

Enter Menu 1 by pressing and releasing the Programming 

button 10 times� If you have performed all the actions cor-

rectly, the Alarm will notify you of it with 3 audible and 

light signals�

◊ 

According to Alarm hardware functions configuring 

(Menu 1) option No� 2 Engine locking is to be selected� To 

do so, press and release the Programming button 2 times� 

The Alarm will inform you on the selected menu option 

number by series of 2 audible and light signals�

◊ 

Enter option No� 2 by pressing and holding the brake pedal� 

The Alarm will inform you on the option setting by repeated 

double audible and light signals because the current (fac-

tory set) option setting is normally closed relay control�

◊ 

Select the normally open relay control by pressing and re-

leasing the Programming button 3 times, for the second 

setting is followed by the third� The Alarm will inform you 

on the option setting with series of 1 audible signal�

◊ 

Exit programming mode by turning the ignition off�

Example 2

Objective:

 You would like to change the factory settings of the Alarm: 

to increase the Anti HiJack activation distance from 100 to 300 meters�

Execution:

◊ 

Turn the ignition on�

◊ 

Enter the PIN code and wait for confirmation�

◊ 

Enter the Alarm setting mode by pressing and releasing 

the Programming button 12 times (start doing it no longer 

than 10 seconds after entering the PIN code)� If you have 

performed all the actions correctly, the Alarm will notify 

you of it with 4 audible and light signals�

◊ 

Select the programming option for setting the Anti HiJack 

activation distance� According to Alarm user settings con-

figuration (Menu 2) table, option No� 5 is to be selected� To 

do so, press and release the Programming button 5 times� 

The Alarm will inform you on the selected menu option 

number by series of 5 audible and light signals�

◊ 

Enter option No� 5 by pressing and holding the brake pedal� 

The Alarm will inform you on the option setting by repeated 

single audible and light signals because the current (fac-

tory set) option setting is 1 (which stands for 100 meters 

distance)�

◊ 

Change option No� 5 setting by pressing and releasing the 

Programming button twice, therefore increasing the option 

setting by 2 (1+2=3)� The Alarm will inform you on the op-

tion setting with series of 3 audible and light signals (300 

meters)�

◊ 

Exit the setting mode by turning the ignition off�

Resetting to factory default settings

The Alarm has a procedure of resetting the programmable settings, 

where all vehicle model settings are removed from Alarm’s permanent 

memory while PIN code and all other programming options are re-

turned to factory original val-

ues�

If certain or all menu op-

tions are password protected 

(see Alarm hardware settings 

programming (Menu 1), p� 

2), only the options that are 

not prohibited will be reset� 

The remaining ones will keep 

their current values�

In order to reset to factory default:

Remove power supply from the Alarm

Press and hold the integrated Programming button (see Fig� 2)

Connect the power supply while holding the button� The Alarm 

will emit dashed audible signal�

Release the button and wait until the dashed signal stops�

Turn the ignition on and enter the current PIN code 

*

An audible trill will be heard, which indicates that resetting to 

factory default has been completed�

Remove the power supply and disconnect the Alarm from CAN 

bus�

    If the Alarm is not installed in the vehicle, please enter the PUK code with 

the integrated button�

Fig� 2� Integrated button

Summary of Contents for TEC-700

Page 1: ......

Page 2: ...ver s door keyless access system remote control or re arming etc that includes arming of the original vehicle alarm Secure condition is left by unlocking the doors with the original remote control or...

Page 3: ...urity mode When opening the trunk with remote control in Security mode ac cessory external sensors inputs are temporarily deactivated sensor input No 1 and sensor input No 2 see Alarm inputs outputs s...

Page 4: ...ity of Speed control If the Speed control is available Anti HiJack waits until the vehicle cov ers a set distance from the moment of Guard mode activation Upon that Anti HiJack goes into the Warning p...

Page 5: ...re no original buttons perceived by the Alarm If the vehicle has original buttons controlled via CAN bus that are perceived by the Alarm this input may be unused Pins No 5 10 Programmable positive inp...

Page 6: ...onnected Programming will stop if Programming button shall not be pressed within 60 seconds Programming sequence 2 1 Power the Alarm and wait for discontinuous audible and light signal 2 2 Enter Menu...

Page 7: ...ut No 2 1 24 4 PIN code entering impulse Programmable output see Programmable outputs functions table 11 output No 9 1 24 23 Comfort timer channel Programmable output see Programmable outputs function...

Page 8: ...nal sensors connection sec tion 1 Multiplex mode for connecting multiplex sensors 2 Standard mode for connecting sensors with dedicated warning and alarm outputs p 9 10 11 Programmable outputs Are des...

Page 9: ...t level signal is formed when vehicle ACC are on 1st key position may match with ignition on cer tain vehicles It is turned off only when the ignition key is out of ignition lock Can be used for corre...

Page 10: ...and leave the programming mode 6 1 Function No 8 Doors hood and trunk programming algorithm applicable only for options No 10 11 and 12 of Menu 1 6 1 1 Set any combination of doors hood and trunk the...

Page 11: ...ontrol allows turning automatic windows closing during vehicle locking on or off p 10 Arming disarming audible confirmation allows setting an arming disarming audible confirmation volume level 1 silen...

Page 12: ...tting the Anti HiJack activation distance According to Alarm user settings con figuration Menu 2 table option No 5 is to be selected To do so press and release the Programming button 5 times The Alarm...

Page 13: ...13 Installation scheme form Keep the filled up scheme in the place which is unavailable for unauthorized persons Mark car alarm element locations on the scheme It will help to find them if required...

Page 14: ...ditions Parameter Value Power supply voltage V 9 15 Maximum current drain in standby mode mA 1 5 Maximum current drain in operation mode A 1 5 Operating temperature C 40 85 Storage temperature C 40 85...

Page 15: ......

Reviews: