background image

2

CAUTION

<

DO NOT REMOVE THE EXTERNAL CASES OR CABINETS TO
EXPOSE THE ELECTRONICS. NO USER SERVICEABLE PARTS
ARE WITHIN!

<

IF YOU ARE EXPERIENCING PROBLEMS WITH THIS PRODUCT,
CONTACT TEAC FOR A SERVICE REFERRAL. DO NOT USE THE
PRODUCT UNTIL IT HAS BEEN REPAIRED.

WARNING: TO PREVENT FIRE OR SHOCK
HAZARD, DO NOT EXPOSE THIS APPLIANCE
TO RAIN OR MOISTURE.

This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there is no
guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following
measures:

•  Reorient or relocate the equipment and/or the receiving

antenna.

•  Increase the separation between the equipment and

receiver.

• Connect the equipment into an outlet on a circuit different

from that to which the receiver is connected.

• Consult the dealer or an experienced electronic technician

for help.

CAUTION

Changes or modifications to this equipments not expressly
approved by TEAC CORPORATION for compliance will void the
user’s warranty.

For U.S.A.

CAUTION

Ensure this product is not exposed to dripping or splashing
and that no object filled with liquids, such as vases, is placed
on the product.

Do not install this equipment in a confined space such as a
book case or similar unit. Allow adequate air circulation
around this product.

IMPORTANT SAFETY INSTRUCTIONS

1) Read these instructions.
2) Keep these instructions.
3) Heed all warnings.
4) Follow all instructions.
5) Do not use this apparatus near water.
6) Clean only with dry cloth.
7) Do not block any ventilation openings. Install in accordance with

the manufacturer’s instructions.

8) Do not install near any heat sources such as radiators, heat

registers, stoves, or other apparatus (including amplifiers) that
produce heat.

9) Do not defeat the safety purpose of the polarized or grounding-

type plug. A polarized plug has two blades with one wider than
the other. A grounding type plug has two blades and a third
grounding prong. The wide blade or the third prong are provided
for your safety. If the provided plug does not fit into your outlet,
consult an electrician for replacement of the obsolete outlet.

10) Protect the power cord from being walked on or pinched

particularly at plugs, convenience receptacles, and the point
where they exit from the apparatus.

11) Only use attachments/accessories specified by the manufacturer.
12) Use only with the cart, stand, tripod,

bracket, or table specified by the
manufacturer, or sold with the apparatus.
When a cart is used, use caution when
moving the cart/apparatus combination to
avoid injury from tip-over.

13) Unplug this apparatus during lightning storms or when unused

for long periods of time.

14) Refer all servicing to qualified service personnel. Servicing is

required when the apparatus has been damaged in any way,
such as power-supply cord or plug is damaged, liquid has been
spilled or objects have fallen into the apparatus, the apparatus
has been exposed to rain or moisture, does not operate normally,
or has been dropped.

<

Do not expose this apparatus to drips or splashes.

<

Do not place any objects filled with liquids, such as vases, on the
apparatus.

<

Do not install this apparatus in a confined space such as a book
case or similar unit.

<

The apparatus draws nominal non-operating power from the AC
outlet with its POWER switch in the off position.

<

The apparatus should be located close enough to the AC outlet
so that you can easily grasp the power cord plug at any time.

<

An apparatus with Class 

!

construction shall be connected to an

AC outlet with a protective grounding connection.

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK). NO USER-
SERVICEABLE PARTS INSIDE. REFER SERVICING TO
QUALIFIED SERVICE PERSONNEL.

The lightning flash with arrowhead symbol, within an
equilateral triangle, is intended to alert the user to the
presence of uninsulated dangerous voltage within the
product’s enclosure that may be of sufficient magnitude
to constitute a risk of electric shock.

The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the
literature accompanying this device.

Summary of Contents for Esoteric D-01

Page 1: ...Monaural D A Converter for Super Audio CD and CD Owner s Manual D 01...

Page 2: ...cluding amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has...

Page 3: ...k If a foreign object should get into the unit contact your dealer or service company When removing the power plug from the wall outlet always pull directly on the plug never yank the cord Do not atte...

Page 4: ...ce and slew rate making a significant contribution to the remarkable sound Word Sync enabled Making Synchronizing with External Equipment Possible The word sync feature operates either in OUT mode as...

Page 5: ...as far upstream as possible NOTES Among the i LINK formats there are MPEG 2 TS for BS digital source and DV for digital video for DVD recorders as well as the i LINK AUDIO A M Protocol Never connect...

Page 6: ...before making connections Read the instructions of each component you intend to use with this unit Be sure to insert each plug securely To prevent hum and noise avoid bundling the signal interconnecti...

Page 7: ...le BNC coaxial digital cable 75 impedance SIGNAL GND connection Use a commercially available insulated stranded wire to connect the signal ground terminal on the unit to the amplifier signal ground No...

Page 8: ...8 AUDIO IN FRONT L Amplifier AUDIO IN FRONT R Amplifier D 01 FRONT L D 01 FRONT R G 0 G 0s P 01 XLR digital cable BNC coaxial cable XLR cable XLR cable Example Connection to the P 01 and the G 0 G 0s...

Page 9: ...igh accuracy Rb IN This is a mode designed for external clocks of a higher degree of precision like a rubidium clock generator Select this mode when this unit is connected to the ESOTERIC G 0s Keep in...

Page 10: ...otates the selection through the following a lit indicator shows the current selection RDOT A fluency digital filter that does upward sample rate conversion This filter has a slow roll off characteris...

Page 11: ...l setting refer to Channel Select in Changing the Settings section page 13 Basic Operation Press the POWER button to turn the unit on 1 When the unit is on the ring surrounding the button lights up Al...

Page 12: ...ton for more than 3 seconds or leave the unit idle for 8 seconds to exit the setup mode 4 Switching off the power without closing the menu display may cause problems Do not turn the unit off Settings...

Page 13: ...f default depending on your preference With this filter switched off there is a chance that unexpected and abnormal noise could be produced and harm your speakers or trip the protection circuit on you...

Page 14: ...deviation in sync is too small and out of the word error detection threshold of the D 01 The WORD indicator blinks The display shows No Word e The word sync mode is selected but there is no clock sou...

Page 15: ...44 1 88 2 176 4 48 96 192 100 kHz 4 down mode 48P 46 08 96P 92 16 192P 184 32 100P 96 kHz Input frequency range WORD IN mode 15 ppm Rb IN mode is designed for extremely precise external clocks like a...

Page 16: ...Audio Interface Receiver ES LINK Decoder DSDqPCM Converter RDOT Digital Filter FIR Digital Filter Master Clock X tal Word Clock Divider PLL RAM LINK RCA WORD OUT WORD IN XLR1 XLR2 IEEE1394 Interface I...

Reviews: