408-35042
Rev C
18
of 26
Feed Position (terminal position over the anvil)
(1) Remove the air supply from the module.
(2) Manually feed the terminal by fully extending the feed and then fully retracting the feed until a
terminal is over the anvil.
(3) If the terminal position is left of the anvil (under-fed), turn the Fine Feed Adjust Screw
clockwise to move the terminal to the right of the anvil (see Figure 18).
NOTE
One (1) “
click
” of the
Fine Feed Adjust Screw equals 0.025mm (0.001 inch) of adjustment.
Figure 18
(4) If the terminal position is right of the anvil (over-fed), turn the Fine Feed Adjust Screw counter-
clockwise to move the terminal to the left of the anvil.
(5) After making an adjustment, retract and extend the feed slide to feed a terminal.
(6) If the terminal is not centered over the anvil, repeat steps (3) thru (5).
Feed Speed
The feed mechanism has been adjusted at the factory to ensure that the terminal is advanced at the
lowest possible speed. In rare occasions, it is possible that the feed speed is not fast enough if the
applicator is used on a fully automatic machine. The feed speed can be adjusted by means of the two
exhaust restrictors.
NOTE
The air feed speed has been set at the factory and should therefore require re-adjustment ONLY in exceptional
circumstances.
NOTE
The speed controls should not be fully opened to maximize feed speed. Excessive feed and/or retract speeds can cause
inconsistent feeds and/or air feed module damage.
NOTE
TE recommends adjusting the Retract Flow Control first to try to speed up the feed cycle.
(1) Hold the control knob while loosening the locking nut with a hex wrench.
(2) Turn the knob clockwise (in) to decrease the speed. Turn the knob counter-clockwise (out) to
increase the speed.
(3) Hold the control knob while tightening the locking nut.
NOTE
TE recommends adjusting the flow controls only ½ turn before testing the feed cycle.
Clockwise
Fine Feed Adjust Screw
2.5mm Ball End
Hex Key Wrench