3. Configure the Cycle Options (Figure 13).
Auto Raise Guards:
When this option is selected, the guards automatically open after a
crimp cycle is completed. If CQM is in use and a defective crimp is detected, the guards d
on’t
open until the crimp error is cleared.
Guards Close + Cycle:
When this option is selected, pressing the foot switch causes the
guards to automatically close and the terminator to cycle to produce a crimp.
Auto Open Cable Clamp Jaws:
This option is only available when the Automatic Cable
Clamp Installed option is selected on the setup dialog. When this option is selected, the cable
clamp jaws automatically open after the completion of a crimp. If CQM is in use and a
defective crimp is detected, the jaws do not open until the crimp error is cleared.
4. The HV-20 Terminator provides a virtual keypad (Figure 14) in lieu of the membrane keypad for
operator control of the terminator. The virtual keypad is accessible on the Sample screen if
Use
CQM
is selected, or on the Production screen if
Use CQM
is
not
selected.
a. To view the virtual keypad, click the virtual keypad button in the dialog corresponding to
whether you have selected to use or not use CQM.
Figure 14: Virtual keypad button
NOTE
Operation of the machine with the virtual keypad is identical to that of the membrane keypad, except where noted.
NOTE
Changes made with the virtual keypad are saved with the selected part if CQM is used.