409-35009
Rev E
39 of 44
4. Press the foot switch to start a terminator cycle and crimp the terminal. The Crimp Quality Monitor
analyzes the crimp.
If the crimp is determined to be good:
a. Open the upper guard by pushing the guard control push button.
o
If manual jaw opening operation was selected, open the jaws by pressing down fully
on the handle.
o
If automatic jaw opening operation was selected, the jaws will open automatically
before the guard opens.
b. Remove the terminated cable.
If the crimp is determined to be defective:
a. Air pressure is supplied to the grip jaws to apply additional force. This makes it difficult for
the operator to remove the cable from the jaws. The guards do not open. An error
message is displayed on the screen.
b. A supervisor or other authorized person must enter a code on the display screen to clear
the error message and continue operation.
c. Open the upper guard by pushing the guard control push button.
o
If manual jaw opening operation was selected, open the jaws by pressing down fully
on the handle.
o
If automatic jaw opening operation was selected, the jaws open automatically before
the guard opens.
d. Remove the defectively terminated cable.
NOTE
The cable should be inspected by a qualified person to determine if the cable needs to be reworked.