6
BA-PB3_IP_EN / F0354800
1.2
Information and obligations for the operator
•
The system may emit interference.
-
The system has been tested in accordance with EMC legislation.
-
The operator must verify and assure electromagnetic compatibility with other
electrical and electronic equipment in the immediate vicinity of the system.
•
Ensure that:
-
Operating personnel have read and understood these operating instructions.
-
Anyone working near the machine is made aware of the dangers and is provided
with the necessary protective equipment.
-
Repairs are only carried out by qualified persons.
•
In particular, make operating personnel aware of the safety instructions in this
document.
•
Always keep the system in a fully functional condition.
•
Any modifications made to the machine will invalidate the operating licence and the
warranty. Exception: if such modifications are expressly authorised by the
manufacturer.
1.3
Intended use
The machine is intended solely for the plasma treatment of surfaces (e.g. metals, textiles,
glass, plastics) to activate, clean, coat or remove residue at atmospheric pressure.
Under no circumstances may the machine be used by non-trained persons.
1.4
Impermissible operating conditions
The machine must not be operated under the following conditions:
•
In explosive (Ex) zones
•
In areas with a severe build-up of dust
•
In environments where the humidity is too high (see technical data, page 12)
•
At altitudes of more than 2000 m above sea level
•
Where there are strong vibrations
1.5
Emissions
The connected plasma generator produces the following emissions:
•
Small amounts of UV light
•
Small amounts of ozone (O
3
) and nitrogen oxides (NOx) The workplace exposure limit
(WEL)may be exceeded. Example:
Plasma gas
Gas flow
Ozone
NOx
Air
35 l/min
1.5 mg/m³
3500 mg/m³
Note!
As a precautionary measure, we recommend using an extraction system with a capacity