background image

LZS-A1000-2 Power Supply

Emissions

Table  1

 AC Line Conducted Emissions 

EN55022/EN55011 

(0.15-30 MHz) Class B

 Radiated RF Emissions 

EN55022/EN55011 

30-1000 MHz Class B

 Powerline Harmonics 

EN61000-3-2 

Class A Limits

 Powerline Fluctuation/Flicker 

EN61000-3-3 

Complies

  

Immunity

 

 Electrostatic Discharge 

IEC61000-4-2 

+/-8 kV Air

  

 

+/-6 kV Contact

 RF Radiated Fields 

IEC61000-4-3 

10 V/m, 80 MHz-2.5GHz

  

 

80% AM @ 1kHZ

 Electrical Fast Transients 

IEC61000-4-4 

+/-2 kV AC Line, Criteria A

  

 

+/-1 kV I/O Line > 3m, Criteria A

 Lightning Surge 

IEC61000-4-5 

+/-2 kV line to GND (CM), Criteria A

  

 

+/-1 kV line to line (DM), Criteria A

 Conducted RF Common Mode 

IEC61000-4-6 

10 V/m RMS, 150 kHz-80 MHz

  

 

80% AM at 1kHz

 Power Frequency Magnetic Field  IEC61000-4-8 

3 A/m

 Voltage Dips/Short Variations 

IEC61000-4-11 

5% of nom. line for .5 cycles - Criteria A

  

 

40% for 5 cycles - Criteria A

  

 

70% for 25 cycles - Criteria A

  

 

95% Dip for 5 seconds -

  

 

Unit should not latch

  

SEMI-F47  

50% of nom. line for 200 msec

  

(110 VAC@1000W, 

70% for 500 msec

  

220 VAC@1500W) 

80% for 10 seconds

  

 

90% for 15 seconds

  

 

0% for 1 cycle or 20mS

 

Additional Immunity

 Ring Wave Lightning Surge Test  IEEE C62.41 

6 kV/30 Ohm Criteria A

This manual is a description of specifications, features and applications of LZS-A1000 power supplies. 

RATINGS AND SPECIFICATIONS*

Maximum Ratings

  

Units 

LZS-A1000-2

Table  2

 Output Voltage Range 

 

10-15.75

 Output Current (Power) @ 60°C** 

A(W) 

84 (1008)

 DC Output @ 12V

 Output Current (Power) @ 70°C** 

A(W) 

50.4 (605)

 

Operating Temperature   

°C 

47-63Hz 100% rated load from -30°C to 60°C derate

  

 

 

 

linearly to 60% @ 70°C (4%/°C) 

  

 

 

 

Over 63Hz to 440Hz 100% rated load from -30°C

  

 

 

 

to 55°C derate linearly to 60% @ 65°C (4%/°C)

 Start-up Temperature 

 

°C 

-40° to +70°

401 Mile of Cars Way, Suite 325 • National City, CA 92154 • 1-800-LAMBDA-4

Revision H : January 2022

Page. 3

Summary of Contents for LZS-A1000-2

Page 1: ...FH QYLURQPHQWDO 7KHVH SURGXFWV DUH 3 DQG WKHUHIRUH FKHPLFDOV VROYHQWV FOHDQLQJ DJHQWV DQG RWKHU OLTXLGV PXVW QRW EH XVHG QYLURQPHQW 7KLV SRZHU VXSSO LV D VZLWFK PRGH SRZHU VXSSO IRU XVH LQ DSSOLFDWLRQV ZLWKLQ D 3ROOXWLRQ HJUHH RYHUYROWDJH FDWHJRU HQYLURQPHQW 0DWHULDO URXS E 3 V DUH XVHG ZLWKLQ LW 2XWSXW RDGLQJ 7KH RXWSXW SRZHU WDNHQ IURP WKH SRZHU VXSSO PXVW QRW H FHHG WKH UDWLQJ VWDWHG RQ WKH SRZ...

Page 2: ...FKDQLFDO HOHFWULF VKRFN DQG ILUH KD DUG SURWHFWLRQ QHUJ D DUGV 7KH PDLQ RXWSXW RI WKLV SURGXFW LV FDSDEOH RI SURYLGLQJ KD DUGRXV HQHUJ 9 LQDO HTXLSPHQW PDQXIDFWXUHUV PXVW SURYLGH SURWHFWLRQ WR VHUYLFH SHUVRQQHO DJDLQVW LQDGYHUWHQW FRQWDFW ZLWK WKH RXWSXW WHUPLQDOV 7KH XQLW FRYHU FKDVVLV ZKHUH DSSOLFDEOH LV GHVLJQHG WR SURWHFW VNLOOHG SHUVRQQHO IURP KD DUGV 7KH PXVW QRW EH XVHG DV SDUW RI WKH H WHU...

Page 3: ... LQ GHU ILQDOHQ HVDPWLQVWDOODWLRQ EHWUDFKWHW ZHUGHQ LWWH NRQWDNWLHUHQ 6LH KU UHJLRQDOHV 7 DPEGD 9HUWULHEVE UR LP DOOH YRQ 5 FNIUDJHQ 8PZHOW LHVH 3URGXNWH VLQG 3 DXV GLHVHP UXQG G UIHQ NHLQH KHPLNDOLHQ VXQJVPLWWHO 5HLQLJXQJVPLWWHO XQG DQGHUH O VVLJNHLWHQ YHUZHQGHW ZHUGHQ 8PJHEXQJ LHVHV 1HW WHLO LVW HLQ 6FKDOWQHW WHLO XU 9HUZHQGXQJ LQ HLQHU 8PJHEXQJ PLW HLQHP 9HUVFKPXW XQJVJUDG hEHUVSDQQXQJVNDWHJRUL...

Page 4: ...6WURPVFKOlJHQ XQG UDQGVFKXW LQ GHP QGJHUlW YRUJHVHKHQ ZHUGHQ HIDKUHQ GXUFK HOHNWULVFKH QHUJLH 9RQ EHVWLPPWHQ 0RGXOHQ NDQQ MH QDFK LQVWHOOXQJ GHU XVJDQJVVSDQQXQJ JHIlKUOLFKH HOHNWULVFKH QHUJLH DXVJHKHQ 9 LH QGJHUlWHKHUVWHOOHU P VVHQ HLQHQ 6FKXW I U 6HUYLFHSHUVRQDO YRU XQEHDEVLFKWLJWHP RQWDNW PLW GHQ XVJDQJVDQVFKO VVHQ GLHVHU 0RGXOH YRUVHKHQ DQQ DXIJUXQG GHU LQVWHOOXQJ JHIlKUOLFKH HOHNWULVFKH QHUJLH...

Page 5: ...DFWHU YRWUH EXUHDX 7 DPEGD OH SOXV SURFKH QYLURQQHPHQW HV SURGXLWV VRQW 3 HW GRQF RQ QH GRLW SDV XWLOLVHU GHV SURGXLWV FKLPLTXHV VROYDQWV GHV SURGXLWV GH QHWWR DJH HW G DXWUHV OLTXLGHV QYLURQQHPHQW IRQFWLRQQHO HWWH DOLPHQWDWLRQ IRQFWLRQQH HQ PRGH FRPPXWDWLRQ SRXU XWLOLVDWLRQ GDQV GHV DSSOLFDWLRQV IRQFWLRQQDQW GDQV XQ HQYLURQQHPHQW DYHF HJUp GH 3ROOXWLRQ HW FDWpJRULH GH VXUWHQVLRQ OOH XWLOLVH GHV F...

Page 6: ...RXU DVVXUHU OD SURWHFWLRQ FRQWUH OHV FKRFV PpFDQLTXHV OHV FKRFV pOHFWULTXHV HW O LQFHQGLH QHUJLHV GDQJHUHXVHV HUWDLQV PRGXOHV SHXYHQW JpQpUHU XQH pQHUJLH GDQJHUHXVH 9 VHORQ OH UpJODJH GH WHQVLRQ GH VRUWLH H IDEULFDQW GH O pTXLSHPHQW ILQDO GRLW DVVXUHU OD SURWHFWLRQ GHV WHFKQLFLHQV G HQWUHWLHQ FRQWUH XQ FRQWDFW LQYRORQWDLUH DYHF OHV ERUQHV GH VRUWLH GH FHV PRGXOHV 6L XQH WHOOH WHQVLRQ GDQJHUHXVH UL...

Page 7: ...UD GLVSRVL LRQH SHU XOWHULRUL UDJJXDJOL RQGL LRQL DPELHQWDOL 4XHVWL SURGRWWL VRQR FODVVLILFDWL FRPH 3 GXQTXH QRQ GHYRQR HVVHUH XWLOL DWL VRVWDQ H FKLPLFKH VROYHQWL SURGRWWL SHU OD SXOL LD R OLTXLGL GL DOWUD QDWXUD PELHQWH 4XHVWR SURGRWWR q XQ DOLPHQWDWRUH D FRPPXWD LRQH GHVWLQDWR DOO XVR LQ DSSOLFD LRQL ULHQWUDQWL LQ DPELHQWL FRQ OH VHJXHQWL FDUDWWHULVWLFKH LYHOOR LQTXLQDPHQWR DWHJRULD VRYUDWHQVLR...

Page 8: ...KH H GDL SHULFROL GL LQFHQGLR 3HULFROL HQHUJHWLFL OFXQL PRGXOL VRQR LQ JUDGR GL HURJDUH HQHUJLD SHULFRORVD 9 D VHFRQGD GHOOD WHQVLRQH LQ XVFLWD LPSRVWDWD SURGXWWRUL GHOOH DSSDUHFFKLDWXUH ILQDOL VRQR WHQXWL D SURWHJJHUH LO SHUVRQDOH GL PDQXWHQ LRQH GDO ULVFKLR GL FRQWDWWR DFFLGHQWDOH FRQ TXHVWL WHUPLQDOL GHL PRGXOL GL XVFLWD 6H LPSRVWDWL VX OLYHOOL FKH QRQ HVFOXGRQR O HURJD LRQH GL HQHUJLD SHULFROR...

Page 9: ...R FRQ VX RILFLQD ORFDO GH 7 DPEGD 0HGLRDPELHQWDO VWRV SURGXFWRV VRQ 3 SRU WDQWR QR SXHGHQ XWLOL DUVH VXVWDQFLDV TXtPLFDV GLVROYHQWHV DJHQWHV GH OLPSLH D QL RWURV OtTXLGRV 0HGLR DPELHQWH VWD IXHQWH GH DOLPHQWDFLyQ HV XQD IXHQWH GH DOLPHQWDFLyQ GH PRGR FRQPXWDGR D XWLOL DU HQ DSOLFDFLRQHV GHQWUR GH XQ HQWRUQR FRQ XQ UDGR GH FRQWDPLQDFLyQ XQD DWHJRUtD GH VREUHWHQVLyQ Q pO VH XWLOL DQ SROLFORUXURV GH ...

Page 10: ... GH SURWHFFLyQ PHFiQLFD FRQWUD GHVFDUJDV HOpFWULFDV FRQWUD HO SHOLJUR GH LQFHQGLRV 3HOLJURV GH HQHUJtD OJXQRV PyGXORV SXHGHQ JHQHUDU HQHUJtD SHOLJURVD 9 GHSHQGLHQGR GH OD FRQILJXUDFLyQ GH OD WHQVLyQ GH VDOLGD RV IDEULFDQWHV GH HTXLSRV ILQDOHV GHEHQ SURWHJHU DO SHUVRQDO GH VHUYLFLR FRQWUD XQ FRQWDFWR DFFLGHQWDO FRQ HVWRV ERUQHV GH VDOLGD GH ORV PyGXORV 6L VH FRQILJXUD GH PRGR TXH SXHGD JHQHUDUVH HQ...

Page 11: ...QWDFWR FRP VHX HVFULWyULR 7 DPEGD PDLV SUy LPR PELHQWDO VWHV SURGXWRV VmR 3 H FRPR WDO QmR VH GHYHP XWLOL DU TXtPLFRV VROYHQWHV DJHQWHV GH OLPSH D H RXWURV OtTXLGRV PELHQWH VWD IRQWH GH DOLPHQWDomR p XPD IRQWH GH DOLPHQWDomR GR PRGR GH FRPXWDomR SDUD XWLOL DomR HP DSOLFDo HV FRP XP 1tYHO GH 3ROXLomR H DPELHQWHV GD FDWHJRULD GH VREUHWHQVmR 6mR XWLOL DGDV SODFDV GH FLUFXLWRV LPSUHVVRV GR JUXSR GH PD...

Page 12: ...D 9 GH DFRUGR FRP D FRQILJXUDomR GD WHQVmR GH VDtGD 2 HTXLSDPHQWR ILQDO GR IDEULFDQWH GHYH JDUDQWLU TXH R SHVVRDO GH DVVLVWrQFLD HVWi SURWHJLGR FRQWUD FRQWDFWRV LQDGYHUWLGRV FRP HVWHV WHUPLQDLV GH VDtGD GR PyGXOR 6H HVVD HQHUJLD SHULJRVD IRU SURGX LGD DV OLJDo HV H RV WHUPLQDLV GR PyGXOR QmR GHYHP VHU DFHVVtYHLV SHORV XWLOL DGRUHV 2 FKDVVLV FREHUWXUD GD XQLGDGH HVWi FRQFHELGR GH IRUPD D SURWHJHU R...

Page 13: ...LZS A1000 2 POWER SUPPLY Installation Operation and Maintenance Manual IM LZSA1000 2 January 2022 Version H ...

Page 14: ...ECIFICATIONS 3 3 FEATURES 5 4 GUIDE TO APPLICATION 7 4 1 Safety Notice 7 4 2 Input Voltage 7 4 3 Output Voltage 7 4 4 Overvoltage Protection Circuit Adjustment 7 4 5 Overtemperature and Overvoltage Shutdown 7 4 6 Auxiliary Control and Alarm Signals 7 5 FIGURES 8 401 Mile of Cars Way Suite 325 National City CA 92154 1 800 LAMBDA 4 Revision H January 2022 Page 1 ...

Page 15: ... power supply label 8 Openings in the product case are designed for ventilation and must not be obstructed when the product is installed and or operated 9 Never push objects of any kind into the product through openings in its case as this could result in electric shock or fire hazard 10 Use copper stranded wire only 12 to 14 AWG rated at 105 C for the AC input All strands must be secured in the t...

Page 16: ...om line for 5 cycles Criteria A 40 for 5 cycles Criteria A 70 for 25 cycles Criteria A 95 Dip for 5 seconds Unit should not latch SEMI F47 50 of nom line for 200 msec 110 VAC 1000W 70 for 500 msec 220 VAC 1500W 80 for 10 seconds 90 for 15 seconds 0 for 1 cycle or 20mS Additional Immunity Ring Wave Lightning Surge Test IEEE C62 41 6 kV 30 Ohm Criteria A This manual is a description of specification...

Page 17: ...ent C 01 Startup Time at 110 VAC input Sec Less than 1 second Overshoot mV No overshoot at turn on or turn off Holdup Time Full Power 220VAC mS 10 Ride through Full Power 220VAC mS 20 Voltage Sag Immunity Full Power 110VAC Semi F47 compliant Load Transient Response 1 of Vo 1A S Recovers to within 25 step load change 0 2 in 1 25 mS Refer to figures 1 7 for supply load connection information Output ...

Page 18: ...9 Signals Isolation Pins 6 and 7 are fully isolated from all other power supply terminals Signal Logic Logic zero below 0 7 V short circuit or open circuit disables power supply output Logic one above 2 5 V enables power supply output Signal Current Draw Current draw from Logic 1 input is less than 4mA Output Response Time Output will be within specified limits within 100 ms of application of logi...

Page 19: ...1 4 Requires No M4 metric hardware supplied with unit Input and Output Connections Table 11 Input Heavy duty terminal block Chassis Ground Tapped hole and screw provided in chassis DC Output Heavy duty bus bars with 1 4 clearance holes for load connections Connection hardware supplied with unit Local Remote voltage sensing Four position lugless connector TB201 see Fig 1 Remote on off Parallel oper...

Page 20: ...gin with respect to the output voltage to avoid nuisance tripping 4 4 OVERVOLTAGE PROTECTION CIRCUIT ADJUSTMENT The overvoltage protection circuit provides an adjustable means of disabling the DC output if it should exceed a pre determined safe value When shipped from the factory the overvoltage level on each LZS unit is set as given in table 6 on page 5 If a different OVP threshold is required it...

Page 21: ...LZS A1000 2 Power Supply Figure 1 PIN Assignments for TB201 and chassis mounted D connector 5 Figures 401 Mile of Cars Way Suite 325 National City CA 92154 1 800 LAMBDA 4 Revision H January 2022 Page 08 ...

Page 22: ...3 Typical Remote Sense Connection Figure 2 Typical Local Sense Connection LS Local Sense S Remote Sense LS Local Sense S Remote Sense 401 Mile of Cars Way Suite 325 National City CA 92154 1 800 LAMBDA 4 Revision H January 2022 Page 9 ...

Page 23: ... or Voltage Source Remote Sensing Figure 4 Remote Voltage Control with an External Programming Resistor or Voltage Source Local Sensing LS Local Sense S Remote Sense LS Local Sense S Remote Sense 401 Mile of Cars Way Suite 325 National City CA 92154 1 800 LAMBDA 4 Revision H January 2022 Page 10 ...

Page 24: ...LZS A1000 2 Power Supply Figure 6 Parallel Operation 401 Mile of Cars Way Suite 325 National City CA 92154 1 800 LAMBDA 4 Revision H January 2022 Page 11 ...

Page 25: ...LZS A1000 2 Power Supply Figure 7 Series Operation 401 Mile of Cars Way Suite 325 National City CA 92154 1 800 LAMBDA 4 Revision H January 2022 Page 12 ...

Page 26: ...LZS A1000 2 Power Supply Figure 8 Outline Drawing 401 Mile of Cars Way Suite 325 National City CA 92154 1 800 LAMBDA 4 Revision H January 2022 Page 13 ...

Page 27: ...0 2 Power Supply Figure 9 Remote Output On Off Control Figure 10 Input Good Inverter Good Output Good Signals 401 Mile of Cars Way Suite 325 National City CA 92154 1 800 LAMBDA 4 Revision H January 2022 Page 14 ...

Reviews: