Communication GUI Guide
GXE600 Series
TDK-Lambda
<Page>
25/41
・
CVCC CFG Dialog
In the dialog box, the enable / disable of digital CV and digital CC is displayed in check box format.
Data of reserved bits cannot be changed.
*Factory setting
bit #
Item
Overview
0
Digital CV
Checked. : The communication register value is enabled as CV reference.
enabled
No check* : T he PV terminal voltage of CN84 or internal trimmer are enabled as CV reference.
1
Digital CC
Checked. : The communication register value is enabled as CC reference.
enabled
No check* : T he CC terminal voltage of CN84 is enabled as CC reference.
(CC is set to 115%T yp. when the CC terminal is open)
By clicking the [OK] button, the data in the display area is updated based on the setting on the dialog.
Please close the dialog and then click the [Write] button.
Otherwise GXE settings will not be updated, so please be careful.
・
Protect CFG Dialog
In the dialog box, enable / disable of latched off is displayed in check box format.
Checked
When the protection function operates, the output of
the power supply will be latched off.
To reset the latched off, the remote Off to On or re-input
the power source are required.
No check
When the protection function operate, the output of
the power supply will automatically recovery.
The recovery time can be adjusted with the automatic recovery
time setting register.
For details of each alarm, refer to "2.7.4 Alarm History Dialog".
bit #
Item
Factory setting
Protection mode
0
SWOCP *
No check
Auto recovery
2
SWOVP
Checked
Latched off
3
HWOVP
Checked
Latched off
* When the SWOCP threshold is larger than the CC reference value, SWOCP will not operate
and the output voltage becomes constant current voltage droop by CC control.
Since the CC reference value at factory setting is set smaller than the threshold value of SWOCP,
the output voltage at overload becomes constant current voltage droop.
By clicking the [OK] button, the data in the display area is updated based on the setting on the dialog.
Please close the dialog and then click the [Write] button.
Otherwise GXE settings will not be updated, so please be careful.