Communication GUI Guide
GXE600 Series
TDK-Lambda
<Page>
23/41
4.2 Holding Reg 1 :
[Read] Button
1) GXE PS Setting 1
Item
Overview
Click the [Read] button to display the device settings of GXE. (All data at once)
By clicking the [Edit] button, it is possible to edit detailed data on the dialog.
In the communication register specifications, the CV/CC target value and protection threshold
are normalized.
However, GXE Access automatically determines the voltage model and converts register values and
voltage / current notation.
The time setting register is set by the time that each reference value is changed from 0% to 100%.
By clicking the individual [Write] button, the setting value of GXE is updated to the edited data.
4.2.1 Acquisition / update of GXE system settings
For the item whose radix is displayed at the left end of the display area,
it is possible to change the display radix by clicking the radix part.
For details on the display radix, see "4.1.3 Meters".
T he display data can be changed within the range described in "7. GXE register list".
Radix part
[Edit] Button
Display area
[Write] Button
T he following data is displayed on the screen. For details, refer to each dialog section.
Item
Overview
Remote CFG
T his make settings related to remote On / Off function.
CVCC CFG
T his make settings related to the CVCC function.
Protect CFG
T his make settings related to the protection function.
By clicking the [Edit] button in each item, it is possible to edit the data on the displayed dialog.
You can also edit data directly in the display area.
By clicking the individual [Write] button, the setting value of GXE is updated to the display area.
When editing directly in the editing area, please confirm that the entered value matches the radix part.
GXE PS Setting 1