Communication GUI Guide
GXE600 Series
TDK-Lambda
<Page>
16/41
3.6 VI Graph Tab
T his tab shows the output derating of GXE and the current operating point.
Make sure that the GXE operating point is displayed inside the output derating curve.
Please be careful that the operating point indication cannot follow when the load fluctuation is fast.
1) Output derating condition input field 2) Operating point 3) Output derating curve
4) Mounting type legend
5) Operating point position
Item
Overview
1
Output derating condition
T his is a field for entering conditions for drawing an output derating curve.
input field
T a
:
Select the ambient temperature of GXE.
Utility Voltage
:
Select voltage input to GXE.
This function does not support input less than 100 Vac.
If input is less than 100 Vac, please check the instruction manual.
Mounting
:
Select the installation direction of GXE.
Refer to "Mounting type legend".
Cover
:
Select the presence or absence of the optional cover.
Cooling
:
Select whether the environment to be used is convection
or forced air cooling.
If you plan to use GXE with forced air cooling, please carefully review
the specifications and instruction manual.
2
Operating point
Indicates the current GXE operating point.
When the load fluctuation is fast, the operating point indication may not follow up.
3
Output derating curve
T his is the output derating curve of GXE.
T he output derating curve depends on the output derating condition input field.
※
There is a region including error in the description. Please use with margin.
4
Mounting type legend
Legend of GXE installation direction.
5
Operating point position
Displays the GXE output operating point as a percentage of the rating.