TDK-Lambda 

EZA2500 series 

Quick Manual / Basic 

• If the built-in fuse is blown, do not use the product even after replacing the fuse as there is risk of abnormality inside. Be sure 
to request repair to our company. 
• For products without built-in protection circuit (element, fuse, etc.), insert fuse at the input to prevent smoke, fire during 
abnormal operation.  

 

As for products with built-in protection circuit, depending on usage conditions, built-in protection circuit 

might not work. It is recommended to provide separate proper protection circuit. 
• For externally mounted fuse do not use other fuses aside from our specified and recommended fuse. 
• This product was made for general purpose electronic equipment for standard industrial use and is not designed for 
applications requiring high safety (such as extremely high reliability and safety requirements. Even though high reliability and 
safety are not required, this product should not be used directly for applications that have serious risk for life and physical safety. 
Take sufficient consideration in fail-safe design (such as providing protective circuit or protective device inside the system, 
providing redundant circuit to ensure no instability when single device failure occurs). 
• When used in environments with strong electromagnetic field, there is possibility of product damage due to malfunction. 
• When used in environment with corrosive gas (hydrogen sulfide, sulfur dioxide, etc.) , there is possibility that they might 
penetrate the product and lead to failure. 
• When used in environments where there is conductive foreign matter or dust, there is possibility of product failure or 
malfunction. 
• Provide countermeasure for prevention of lightning surge voltage as there is risk of damage due to abnormal voltage. 
• Connect together the frame ground terminal of the product and the ground terminal of the equipment for safety and noise 
reduction. If these grounds are not connected together, there is risk of electric shock. 
• Parts with lifetime specifications (built-in fan, electrolytic capacitor) are required to be replaced periodically.  

 

Set the overhaul 

period depending on the environment of usage and perform maintenance.  

 

Also, note that there are cases when EOL products 

cannot be overhauled.  
• Take care not to apply external abnormal voltage to the output. Especially, applying reverse voltage or overvoltage more than 
the rated voltage to the output might cause failure, electric shock or fire. 
• Do not use in special environment such as places directly exposed to sunlight, dew condensation, moisture, rain, strong 
electro-magnetic field, or corrosive gas (hydrogen sulfide, sulfur dioxide).  
• This product has a built-in fan for air-cooling. Do not block the air intake and exhaust. 
• The output of this product is considered to be a hazardous energy level (The voltage is 2V or more and the power is 240VA or 
more). It must not be made accessible to users. Protection must be provided for Service Engineers against indirect contact with 
the output terminals and/or to prevent tools being dropped across them. While working on this product, the DC input power must 
be switched off and the input and output voltage should be zero. 
• When short the output during operation, there is damage inside the converter. 
• When change abrupt in Input voltage during operation, there is a Risk of damage inside the converter. 
• When use the Electric storage device, Please refer to the manual of electric storage device and use the appropriate protection 
device. 
 

Note 

• There is a possibility machining traces remain on sheet metal of product. 
• Consider storage of the product at normal temperature and humidity avoiding direct exposure to sunlight at environment with 
minimal temperature and humidity changes. Storage of product at high temperature, high humidity and environments with 
severe changes in temperature and humidity might cause deterioration, and occurrence of condensation in the product. 
• When disposing product, follow disposal laws of each municipality. 
• Published EMI (CE, RE) or immunity is the result when measured in our standard measurement conditions and might not 
satisfy specification when mounted and wired inside end-user equipment.  

 

Use the product after sufficiently evaluating at 

actual end-user equipment. 
• Catalogue, contents of the instruction manual may be changed without a prior notice. Refer to latest catalogue or instruction 
manual. 
• Reproduction or reprinting the instruction manual or its portion is forbidden without our permission. 

Summary of Contents for EZA2500 Series

Page 1: ...tc Please stop using it immediately and shut off the product It might lead to fire and electric shock In such cases please contact us Do not attempt repair by you as it is dangerous for the user Do no...

Page 2: ...of usage and perform maintenance Also note that there are cases when EOL products cannot be overhauled Take care not to apply external abnormal voltage to the output Especially applying reverse volta...

Page 3: ...300 380 VDC AC DC power supply CNVCommCC is distributed by TDK lambda Contents 1 Basic operation of EZA boost step down 2 EZA panel and terminal description 3 What to prepare before using EZA a Create...

Page 4: ...during the conversion operation There are roughly two ways to switch the direction of power conversion and there are two modes a mode in which it switches over upon receiving an external command signa...

Page 5: ...ary Switch The rotary switch functions as the RS 485 address setting for this converter It is used to set the lowest digits last 4 bits and DIP SW is used to set the highest digits Light up at Dischar...

Page 6: ...Serial Interface Connector LAN cable can be used with the same shape as Ether net used on RJ 45 PC LAN However it is not compatible with LAN Ether net Check the pin assignment of RS 485 in the instru...

Page 7: ...refer to p4 of EZA 2500 communication manual which is separately distributed The following points are listed below Item Specification Note EZA side connector RJ45 It is the same shape as Ether net of...

Page 8: ...rsonal computer using RS 485 In the figure the inverter is supposed to be capable of bidirectional power conversion from AC to DC from DC to AC called a regenerative function and supplies electric pow...

Page 9: ...voltage power supply eg GENESYS series of TDK lambda that can output 300 380 VDC instead of DC AC inverter However when the EZA is discharged the constant voltage power supply may be damaged so be sur...

Page 10: ...RS485 converter driver is installed EZA does not have volume for output adjustment Output voltage current etc are all set by setting parameters via RS485 Install CNVCommCC according to the operation m...

Page 11: ...ED that is visible through the punching metal on the back panel lights up Confirm that you are connected as shown in p8 or p9 of this manual Launch CNVCommCC exe on your computer The following message...

Page 12: ...gs and opens the port If opening the port fails an error message is displayed Click the CLOSE button to close the window Check the COM port and the EZA DIP switch settings and start over from step Com...

Page 13: ...setting panel Please select the EZA address and PC address you want to communicate with Set the address of the EZA you want to communicate with in communication with EZA Turn ON the single target radi...

Page 14: ...f the sensor for each voltage current power internal temperature of EZA are displayed on the screen When communication with the EZA fails Timeout is displayed in Communication status at the upper righ...

Page 15: ...on of the menu bar in a state where it can communicate with EZA Calibration is done automatically Calibration information is automatically acquired from EZA Once calibration is performed information i...

Page 16: ...ng parameters to the area surrounded by the red line in the above figure Target Battery Voltage 50 V Limit of Battery Voltage for Discharging 40 V Turn on the radio buttons of Battery Over Charging Pr...

Page 17: ...it of Battery of the battery is now set to 1A And when the battery reaches the target voltage the EZA controls the charge current to 0A In the unlikely event that the battery voltage drops below 38V o...

Page 18: ...driving and Battery CC respectively surrounded by the red line in the above figure Click the Battery CV EZA starts and the fan starts rotating EZA charges the battery with charging current 1 A until i...

Page 19: ...485 is explained below Click the Main tag in a state where it can communicate with EZA 02 Converter Status Click the READ in Converter Status Charging is displayed in the square under Running State Cl...

Page 20: ...moved the operation state will not return unless the return signal is input In this case the red LED of ALM on the front panel will light and pin1 of the external signal connector CN will be open To r...

Page 21: ...ual Basic Click the Main tag in a state where it can communicate with EZA Click the READ in 09 Alarm Operation status is displayed in the square If there are multiple lines you can confirm by clicking...

Page 22: ...o 0 01 1 the grid target voltage drops by 3 8 V at 7 8A output It should be noted that the input unit in CNVCommCC is CIB Current Limit of Battery A 52 006 0 56 77 Nominal value is 52A DIG Current Lim...

Page 23: ...02 0 12 Set deviation of volts for warning of discharging lower limit When Battery Volt DLB DDB Warning signal is outputted DDR Deviation of Volts for Cancel Warning of Discharging Lower Limit V 0 0 1...

Page 24: ...24 TDK Lambda EZA2500 series Quick Manual Basic...

Reviews: