05/2013
5
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88
Subject to technical changes.
FAX: +49 (0) 41 94/ 9 88 129
•
Mail: [email protected]
PI_FVM1000-0400_uk.doc Version: 1
Indication and operating elements
Labelling
Function
LED, green:
indicates operational
readyness
•
OFF: device is out of operation
•
ON: operating voltage is on
•
blinks: reload to factory settings
LED, yellow:
indicates programming
mode
•
OFF: not in programming mode, waiting for PIN input
•
blinks: device is in programming mode, waiting for
command input
•
blinks fast (for 3 s): incorrect input
•
ON (for 3 s): positive input acknowledgement
LED, red:
error indication
•
OFF: device is in stand-by mode, no error detected
•
flashes: total error indication
Reset button
button to reload the
factory settings WE
•
to reset the FVM1000
•
to reload the factory settings of the FVM1000
brightness control
•
adjustable from -11 dB to +5 dB
from 0.28 Vss to 1.82 Vss (factory setting =1 Vss)
Technical data
connection termi-
nals video IN
button to reload
factory settings
J1
matching
resistor
indication for opera-
tion voltage, LED
green
indication programming
mode, LED yellow
error indication SD card
and TCS:BUS, LED red
slot for SD card
brightness
control
infrared receiver for
remote control
connection termi-
nals video OUT
reset button