14
05/2013
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88
Subject to technical changes.
FAX: +49 (0) 41 94/ 9 88 129
•
Mail: [email protected]
PI_FVM1000-0400_uk.doc Revision: 1
Deleting serial numbers of indoor stations
Initiate the
programming
if not already realised
Enter
…
* 3 # SNo 1 #
•
entry with SNo 1 is deleted, max. 32 serial
number pairs can be trained
•
enter always SNo 2 = 0, if only SNo 1should
be trained
(SNo = serial
number)
Entry deleted,
images in the index
deleted
•
a positive acknowledgement tone sounds,
the yellow LED is ON for 3 s
•
then the yellow LED blinks
The entry and the index with the included im-
ages are deleted on the SD card.
Invalid value
(SNo 1 unknown or
enter a SNo 2)
A negative acknowledgement tone sounds
when pressing the #-button.
The yellow LED blinks fast for 3 s,
then blinks again
Set the delay time of the automatic image recording
Initiate the
programming
if not already realised
Enter
…
* 4 # Value #
Value = 1 to 30 s
(WE* = 1 s)
Delay time
is set
•
A positive acknowledgement tone sounds,
the yellow LED lights up for 3 s.
•
then the yellow LED blinks
The image recording starts x seconds after an
incoming door call.
Invalid value
A negative acknowledgement tone sounds
when pressing the #-button.
The yellow LED blinks fast for 3 s,
then blinks again
*WE = factory setting