Change the master code 

Initiate the  
programming 

 

 

if not already realised 

 
 

 

Enter 
 
 

 

 

 

 

 

 

 

* 98 # Alter Mastercode #  
Neuer Mastercode # Neuer Mastercode # 
Mastercode = 6-stellige Zahl  

 

!

 

ACHTUNG: Aus Sicherheitsgründen 
sollte der werksseitig voreingestellte 
Mastercode bei der Inbetriebnahme 
geändert werden! 

 

 

 

Master code changed 
 
 
 

 

 
 

  A positive acknowledgement tone sounds, 

the yellow LED lights up for 3 s 
 
 

  then the yellow LED blinks 

 
 

 

   

 

 

   

 

Incorrect entry, un-
known master code 
 
 
 
 

 

A negative acknowledgement tone sounds 
when pressing the #-button. 
 
The yellow LED blinks fast for 3 s,  
 
then blinks again 
 

 

    

 

 

    

 

 

Setting the date 

Initiate the  
programming 

 

 

if not already realised 

 
 

 

Enter 
 
 

 

 

 

  

 

 

 

* 95 # YY # MM # DD # format # 
YY = year, MM = month, DD = day 
(year: as of 2000) 
 
format   

 

 

(WE* = 0) 

  = 0  DD.MM.YYYY 
  = 1  MM.DD.YYYY 
  = 2  YYYY- MM-DD 

 

 

Encoding is set 
 
 

 

 
 

  A positive acknowledgement tone sounds, 

 the yellow LED lights up for 3 s 
 

  then the yellow LED blinks 

 

 

 

   

 

 

   

 

Invalid value  
 
 
 

 

A negative acknowledgement tone sounds 
when pressing the #-button. 
 
The yellow LED blinks fast for 3 s,  
 
then blinks again 

 

    

 

 

    

 

*WE = factory setting 

Summary of Contents for FVM1000

Page 1: ...rolSysteme AG TCS Hotline Gerrmany 49 0 41 94 9 88 11 88 Subject to technical changes FAX 49 0 41 94 9 88 129 Mail info tcsag de PI_FVM1000 0400_uk doc Version 1 Product information Central image buff...

Page 2: ...of delivery 3 Safety instructions 3 Device overview 4 Indication and operating elements 4 Technical data 5 Intended use 5 Short description 5 Connect the lines 6 Connection lines to the TCS system 6 W...

Page 3: ...ster code 16 Setting the date 16 Setting the time 17 Reload to factory settings 17 End the programming 18 Settings 18 Setting the image quality 18 Operation 19 Operation in one family mode and basic m...

Page 4: ...y regulations for telecommunication systems according to VDE 0800 and EN60950 International Safety Standard for Infor mation Technology Equipment must be observed separated conduit of heavy and low cu...

Page 5: ...for 3 s incorrect input ON for 3 s positive input acknowledgement LED red error indication OFF device is in stand by mode no error detected flashes total error indication Reset button button to reload...

Page 6: ...d use The FVM1000 is a separate memory for images image series with 4 images It is suitable for the installation in a distribution box DIN rail mounting In one family mode and basic mode the FVM1000 c...

Page 7: ...crewdriver to connect the lines and to avoid damaging the device Connection lines to the TCS system acceptable cross section diameter 0 08 0 82 mm2 0 32 1 0 mm max number of wires per terminal contact...

Page 8: ...ly or as the last device at the end of a TCS BUS video strand the terminating resistor J1 must stay plugged position ON see type label Otherwise the terminating resistor J1 has to be removed Ensure th...

Page 9: ...e family home and basic mode set the function key of the indoor station The function key of the indoor station must be assigned with the control function 8 The control function 8 is not allowed to be...

Page 10: ...e buffering 1 activated date format 0 DD MM YYYY master code serial number FVM1000 brightness control 0 dB fully counterclock wise position Reload factory settings via push button Attention When reloa...

Page 11: ...ocated The recall is realised via special protocols For detailed information on operation see instruction manual or product information of the video indoor station Programming with the infrared remote...

Page 12: ...e LED yellow is OFF Master code WE serial number of the FVM1000 with 6 digits Device is ready for programming A positive acknowledgement tone sounds LED yellow lights up for 3 s LED yellow blinks then...

Page 13: ...stations Initiate the programming if not already realised Enter 1 SNo 1 SNo 2 max 32 serial number pairs can be trained1 always enter SNo 2 0 if only SNo 1 should be trained SNo serial number Serial...

Page 14: ...3 s then the yellow LED blinks The entry and the index with the included im ages are deleted on the SD card Invalid value SNo 1 unknown or enter a SNo 2 A negative acknowledgement tone sounds when pre...

Page 15: ...door call x images are stored every second Invalid value A negative acknowledgement tone sounds when pressing the button The yellow LED blinks fast for 3 s then blinks again Set the video AS border I...

Page 16: ...ive acknowledgement tone sounds when pressing the button The yellow LED blinks fast for 3 s then blinks again Delete all images Initiate the programming if not already realised Enter 94 master code ma...

Page 17: ...ive acknowledgement tone sounds the yellow LED lights up for 3 s then the yellow LED blinks Incorrect entry un known master code A negative acknowledgement tone sounds when pressing the button The yel...

Page 18: ...nt tone sounds when pressing the button The yellow LED blinks fast for 3 s then blinks again Reload to factory settings Attention When reloading the factory settings all images are deleted the master...

Page 19: ...s realised for 2 min A positive acknowledgement tone sounds the yellow LED lights up for 3 s the yellow LED expires Programming with TCSK01 Via Service Device TCSK 01 no programming can be realised Se...

Page 20: ...ally Condition An image can only be stored manually if the video image is shown or a voice connection is established voice connection after a door call came in or after pressing the image button and s...

Page 21: ...es is not permitted Infrared remote control Commissioning Pull out foil stripes in the direction of the arrow carefully Keep the remote control We recommend to fix the infrared remote control after th...

Page 22: ...wet cloth Remove stronger stains with a mild household cleaner Conformity This device meets the requirements of the EU standard 2004 108 EG by fulfilling the standards EN 61000 6 3 EN 61000 6 1 Declar...

Page 23: ...29 Mail hotline tcsag de PI_FVM1000 0400_uk doc Version 1 Warranty We offer a simplified processing in case of warranty for electricians Please note our conditions of sale and delivery available under...

Page 24: ...24 05 2013 TCS T rControlSysteme AG TCS Hotline Germany 49 0 41 94 9 88 11 88 Subject to technical changes FAX 49 0 41 94 9 88 129 Mail hotline tcsag de PI_FVM1000 0400_uk doc Revision 1...

Page 25: ...ges FAX 49 0 41 94 9 88 129 Mail hotline tcsag de PI_FVM1000 0400_uk doc Version 1 Service Please send your questions and inquiries to hotline tcsag de Headquarters TCS T rControlSysteme AG Geschwiste...

Reviews: