background image

 

10/2012 

TCS TürControlSysteme AG, TCS Hotline Germany:  [email protected]

 

Subject to technical changes. 

FAX: +49 (0) 41 94/ 9 88 129 

 

PI_AVC11010-uk       1A 

 

Table of contents 

 

Safety instructions ............................................................................................................. 2

 

General safety regulations ............................................................................................... 2

 

Installation 

– protective measures .................................................................................... 3

 

Device overview ................................................................................................................. 3

 

Technical data .................................................................................................................... 4

 

Intended use ....................................................................................................................... 5

 

Short description ............................................................................................................... 5

 

Installation .......................................................................................................................... 5

 

Notes on the installation site ............................................................................................ 5

 

Mounting height ................................................................................................................ 5

 

win:clip system ................................................................................................................. 5

 

Install the front-door station .............................................................................................. 6

 

Connect the lines ............................................................................................................... 7

 

General note .................................................................................................................... 7

 

Connecting ....................................................................................................................... 7

 

5-wire special operation ................................................................................................... 7

 

Commissioning .................................................................................................................. 7

 

Function check name plate illumination ............................................................................ 7

 

Set volume of microphone and loudspeaker .................................................................... 8

 

Labelling the name plate ................................................................................................... 8

 

General information on the conduit in TCS video systems ........................................... 8

 

6-wire operation................................................................................................................ 8

 

Principle loop resistance ............................................................................................... 9

 

Measure loop resistance ............................................................................................... 9

 

Cleaning ............................................................................................................................ 10

 

Repair ................................................................................................................................ 10

 

Exchange an indoor station 

– programming bell buttons ................................................ 10

 

Conformity ........................................................................................................................ 12

 

Information on disposal .................................................................................................. 12

 

Warranty ........................................................................................................................... 12

 

Service .............................................................................................................................. 12

 

 
 

Safety instructions 

General safety regulations 

 

!

 

Attention! Mounting, installation, commissioning and repair of electronic devices have 
to be carried out only by qualified electricians. The latest accident prevention regula-
tions must be observed. 

 
For working on systems with main connection of 230 V alternating voltage, the safety re-
quirements according to DIN VDE 0100 must be observed. 
 
When installing TCS: BUS

®

 systems, the general safety regulations for telecommunication 

systems according to VDE 0800 must be observed. Inter alia: 

  separated conduit of heavy current and low current lines, 

Summary of Contents for AVC11010-0010

Page 1: ...ntrolSysteme AG TCS Hotline Germany info tcs germany de Subject to technical changes FAX 49 0 41 94 9 88 129 PI_AVC11010 uk 1A Product information Video front door station for video pack S 11010 AVC11...

Page 2: ...nformation on the conduit in TCS video systems 8 6 wire operation 8 Principle loop resistance 9 Measure loop resistance 9 Cleaning 10 Repair 10 Exchange an indoor station programming bell buttons 10 C...

Page 3: ...tandard communication lines e g J Y St Y with 0 8 mm diameter existing lines modernisation with deviating cross sections can be used in compliance with the loop resistance Installation protective meas...

Page 4: ...acrylic glass Weight 380 g Acceptable ambient temperature 20 C 50 C Input current I a 0 4 mA I P 140 mA Max input current I Pmax 156 mA Camera bw camera CCD sensor 380 TVL Focal length f 3 6 mm Light...

Page 5: ...identical in construction R terminal to connect an extended function door release door release time at R terminal ex works 3 seconds adjustable with Service Device door stand by time to control the sh...

Page 6: ...illumination see installation 2 Push the enclosed win clip key into the small opening within the loudspeaker cover Press the key into the opening until stop and keep it in this position 3 Push the nam...

Page 7: ...switch in the video front door station must be set to right in 5 wire operation 5W Commissioning First install the system completely than connect it to the main voltage Install all devices of the syst...

Page 8: ...to print out the name plates on a resistant special foil Order foils directly from TCS writable polyester foil for name plates DIN A4 Open the video front door station Remove the name plate glass car...

Page 9: ...resistances line length a b M P in m line diameter 0 6 mm 0 8 mm loop resistance in 10 1 28 0 71 20 2 55 1 43 30 3 83 2 14 40 5 10 2 86 50 6 38 3 57 60 7 65 4 29 70 5 00 80 5 71 90 6 43 100 7 14 Prin...

Page 10: ...he bell button of a front door station and is further stored within the EEPROM of the front door station Ensure that the new indoor station is connected to the TCS BUS and the mains voltage is switche...

Page 11: ...grammed compare product information of the front door station 1 If there sounds a Progsperr tone instead the front door station is equipped with a programming lock The programming lock can be deactiva...

Page 12: ...e The material used are recyclable Please do help protecting our environment and dispose the device via a collecting point for electronic scrapp Dispose the parts of the packaging in collecting tanks...

Reviews: