background image

 

10/2012 

TCS TürControlSysteme AG, TCS Hotline Germany:  [email protected]

 

Subject to technical changes. 

FAX: +49 (0) 41 94/ 9 88 129 

 

PI_AVC11010-uk       1A 

 

Set volume of microphone and loudspeaker 

 

!

 

Use the enclosed small screwdriver for the setting! 

 

Ex works the volumes are set on an average val-
ue. A modification is not always necessary. 
Please observe when setting the values: 
The amplification of the loudspeaker and the mi-
crophone cannot be set independently of one 
another. Too high volumes cause a feedback 
effect (whistling). 

Volume control 

 

Microphone 

 

Regulate the 

 

volume at the 

 

indoor station

 

Loudspeaker  

Regulate the 
volume at the 
front-door station

 

 

 
 

 

Labelling the name plate 

 

  Label the enclosed name plate foil (special foil). 

 

We recommend to print out the name plates on a resistant special foil.  
Order foils directly from TCS: writable polyester foil for name plates DIN A4. 
 
 

  Open the video front-door station. 

Remove the name plate glass carefully. 
Pull off the plug of the name plate illumina-
tion. 

  Open the name plate glass: 

Insert the win:clip key into the small open-
ing and twist the key. 

  Put in the prepared foil and close the name 

plate glass again. 

 

 

 
 
 

 

General information on the conduit in TCS video systems  

6-wire operation 

The 6-wire operation is the standard operating mode. Video operation which use two sepa-
rated ground lines (b and M). 
The conduit is determined by structural conditions and is only limited by length.  

  Please observe when selecting the length of the cable: the loop resistance must not 

exceed a max. of 8 

Ω at a-b and M-P (table 1). 

  If the loop resistance is > 8 

Ω: plan multiple wiring of the strands (double twisted lines). 

  optinal strand or star formed wiring  

Summary of Contents for AVC11010-0010

Page 1: ...ntrolSysteme AG TCS Hotline Germany info tcs germany de Subject to technical changes FAX 49 0 41 94 9 88 129 PI_AVC11010 uk 1A Product information Video front door station for video pack S 11010 AVC11...

Page 2: ...nformation on the conduit in TCS video systems 8 6 wire operation 8 Principle loop resistance 9 Measure loop resistance 9 Cleaning 10 Repair 10 Exchange an indoor station programming bell buttons 10 C...

Page 3: ...tandard communication lines e g J Y St Y with 0 8 mm diameter existing lines modernisation with deviating cross sections can be used in compliance with the loop resistance Installation protective meas...

Page 4: ...acrylic glass Weight 380 g Acceptable ambient temperature 20 C 50 C Input current I a 0 4 mA I P 140 mA Max input current I Pmax 156 mA Camera bw camera CCD sensor 380 TVL Focal length f 3 6 mm Light...

Page 5: ...identical in construction R terminal to connect an extended function door release door release time at R terminal ex works 3 seconds adjustable with Service Device door stand by time to control the sh...

Page 6: ...illumination see installation 2 Push the enclosed win clip key into the small opening within the loudspeaker cover Press the key into the opening until stop and keep it in this position 3 Push the nam...

Page 7: ...switch in the video front door station must be set to right in 5 wire operation 5W Commissioning First install the system completely than connect it to the main voltage Install all devices of the syst...

Page 8: ...to print out the name plates on a resistant special foil Order foils directly from TCS writable polyester foil for name plates DIN A4 Open the video front door station Remove the name plate glass car...

Page 9: ...resistances line length a b M P in m line diameter 0 6 mm 0 8 mm loop resistance in 10 1 28 0 71 20 2 55 1 43 30 3 83 2 14 40 5 10 2 86 50 6 38 3 57 60 7 65 4 29 70 5 00 80 5 71 90 6 43 100 7 14 Prin...

Page 10: ...he bell button of a front door station and is further stored within the EEPROM of the front door station Ensure that the new indoor station is connected to the TCS BUS and the mains voltage is switche...

Page 11: ...grammed compare product information of the front door station 1 If there sounds a Progsperr tone instead the front door station is equipped with a programming lock The programming lock can be deactiva...

Page 12: ...e The material used are recyclable Please do help protecting our environment and dispose the device via a collecting point for electronic scrapp Dispose the parts of the packaging in collecting tanks...

Reviews: