background image

 

10 

10/2012 

TCS TürControlSysteme AG, TCS Hotline Germany:  [email protected]

 

Subject to technical changes. 

FAX: +49 (0) 41 94/ 9 88 129 

 

PI_AVC11010-uk       1A 

 

Cleaning 

 

!

 

Avoid water from entering the device! 
Do not use any abrasive detergents! 

 

Clean the device with a dry or slightly wet cloth. 
Remove stronger stains with a mild household cleaner. 
 
 
 

Repair 

Replacing an indoor station 

– programming bell buttons 

Basics 

  All devices at the TCS:BUS have a unique serial number.  

  Programming a bell button means that the serial number of an indoor station is allocat-

ed to the bell button of a front-door station and is further stored within the EEPROM of 
the front-door station.  

  Ensure that the new indoor station is connected to the TCS:BUS and the mains voltage 

is switched ON (the operation LED at the power supply and control unit is ON). Further 
ensure that the access to the flat is granted during the programming. 

  This instruction describes the allocation of a serial number to a bell button without set-

ting a programming lock. To deactivate a programming lock, a Service Device TCSK-
01or the configuration software confi

go™ is needed. 

 

 

Initiate 

Power supply and control unit 

 

 

 

 
 

shortly press 

LED blinks 

 

 
 
 

 

 
 

 

Programming mode of the system is switched ON  

 

Delete a button

a)

 

 

 

 

 
 
 

   

 

 

 
 
 

 

 

 

Press until the delete-tone melody sounds 

1)

 

 

release 

 
 
 
 
 

Summary of Contents for AVC11010-0010

Page 1: ...ntrolSysteme AG TCS Hotline Germany info tcs germany de Subject to technical changes FAX 49 0 41 94 9 88 129 PI_AVC11010 uk 1A Product information Video front door station for video pack S 11010 AVC11...

Page 2: ...nformation on the conduit in TCS video systems 8 6 wire operation 8 Principle loop resistance 9 Measure loop resistance 9 Cleaning 10 Repair 10 Exchange an indoor station programming bell buttons 10 C...

Page 3: ...tandard communication lines e g J Y St Y with 0 8 mm diameter existing lines modernisation with deviating cross sections can be used in compliance with the loop resistance Installation protective meas...

Page 4: ...acrylic glass Weight 380 g Acceptable ambient temperature 20 C 50 C Input current I a 0 4 mA I P 140 mA Max input current I Pmax 156 mA Camera bw camera CCD sensor 380 TVL Focal length f 3 6 mm Light...

Page 5: ...identical in construction R terminal to connect an extended function door release door release time at R terminal ex works 3 seconds adjustable with Service Device door stand by time to control the sh...

Page 6: ...illumination see installation 2 Push the enclosed win clip key into the small opening within the loudspeaker cover Press the key into the opening until stop and keep it in this position 3 Push the nam...

Page 7: ...switch in the video front door station must be set to right in 5 wire operation 5W Commissioning First install the system completely than connect it to the main voltage Install all devices of the syst...

Page 8: ...to print out the name plates on a resistant special foil Order foils directly from TCS writable polyester foil for name plates DIN A4 Open the video front door station Remove the name plate glass car...

Page 9: ...resistances line length a b M P in m line diameter 0 6 mm 0 8 mm loop resistance in 10 1 28 0 71 20 2 55 1 43 30 3 83 2 14 40 5 10 2 86 50 6 38 3 57 60 7 65 4 29 70 5 00 80 5 71 90 6 43 100 7 14 Prin...