10/2012
7
TCS TürControlSysteme AG, TCS Hotline Germany: [email protected]
Subject to technical changes.
FAX: +49 (0) 41 94/ 9 88 129
PI_AVC11010-uk 1A
Connect the lines
General note
!
Connect the lines with the enclosed small screwdriver to prevent damaging the device.
Connecting
Strip the cable ends.
Connect the lines depending on the type of system and according to the wiring diagram
in the product information
Video home:pack S-11010
.
5-wire special operation
If there are only 5 wires available, you can use the
5-wire special operation.
The M-wire is to be connected to b via a bridge.
The slide switch in the video front-door station
must be set to
“right” in 5-wire operation (”5W“).
Commissioning
!
First install the system completely, than connect it to the
main voltage!
Install all devices of the system completely.
V1 and V2 must not be connected to P-, a- or b-wire. When connecting the video wires
V1 (+) and V2 (-) please observe the polarity.
Check the a-, b- and P-wire against each other on short-circuits.
Switch ON the mains voltage.
Both LEDs of the video indoor station are blinking 3 x green. The system is ready to op-
erate.
Function check name plate illumination
The video front-door station is equipped with a light sensor. When the environment is suffi-
ciently illuminated, the name plate illumination turns OFF.
Check the function of the sensor by covering it. The name plate illumination turns ON.