background image

 

01/2013 

TCS TürControlSysteme AG, TCS Hotline Deutschland:  [email protected] 

 

Subject to technical changes. 

www.tcsag.de 

PI_AMI1090x-uk   1A 

 1 

Initiate 

 

Switch on the programming mode of the system

  

Power supply and control unit 

 

 

 

 
 
 

 

 
 

  

 

Shortly press the 
RUN/PROG push button     LED blinks   

 

Namenplate of the bell button module blinks. 
Programming mode of the system is switched on 

 

2a 

Via voice connection 

 

er

 

 
 
 
 

  

 

 

 
 
 
 

 

 

 

 

 
 
 

 

 

 

 

 

 

 

 

 

 

◄6s► 

 

Establish voice connec-
tion to the front-door 
station 

 

Press button until the 
negative acknowledgement  
and positive acknowledgement  

 

... and a ring tone at 
the front-door and 
indoor station sound

1)

 

Release 

 

2b 

alternatively

: Via floor push button 

(indoor station is not available)

 

 

 

 
 

  

 

  

 
 
 
 
 

 

 

 

 
 

 

 

 
 
 
 

 

 

 
 
 
 

 

 

 

 

 
 
 

 

 

 

 

 

 

 

◄6s► 

 

Press the floor push but-
ton two times, every time 
a ring tone sounds 

 

Press the button until a 
negative acknowledgement  
and positive acknowledgement 

 

... and a ring tone at 
the front-door and 
indoor station sound 

1)

 

Release 

     Repeat the steps until all bell buttons are programmed 

 

End 

Power supply and control unit 

 

 

 

 
 
 

 

 
 

       oder     

Shortly press the 
RUN/PROG push button     LED is on 

 

Namenplate of the bell button module ON (or OFF). 
Programming mode of the system is switched off. 

 

1) If there sounds a Progsperr tone instead, a programming lock at the front-door station is activated. The 

programming lock can only be deactivated with a Service Device TCSK-01 or the configuration software 
configo

TM

.

 

Summary of Contents for AMI1090 Series

Page 1: ...ries AMI Bell button module AMI1090x AMI10901 1 button AMI10902 2 buttons AMI10903 3 buttons AMI10904 4 buttons Note on the validity of this product information This product information states specifi...

Page 2: ...ines 4 Connect the module within the front door station 4 in connection with a built in door loudspeaker module AMI11100 4 in connection with a display module AMI1010x 5 Configuration 5 Pre settings e...

Page 3: ...oor loudspeaker module AMI11100 or a codelock module AMI11200 TCS BUS connection necessary Short description bell button modules in the variations with 1 to 4 buttons connection via the connection cab...

Page 4: ...cted to a built in door loudspeaker module AMI11100 or to a module with connection cable with 4 pins in connection with a built in door loudspeaker module AMI11100 Built in door loudspeaker module Rem...

Page 5: ...ent switchting lights AS address 0 backlight ON programming lock OFF Configuration options manual TCSK 01 configoTM as of 1 7 1 delete a bell button assign a bell button with light switch function x x...

Page 6: ...already programmed bell button can be programmed anew the program ming has to be deleted The AS addresses of the bell button modules and of the built in door loudspeaker module resp display module mu...

Page 7: ...e indoor station 1 Repeat the steps until all bell buttons are programmed 3 End Power supply and control unit or Shortly press the RUN PROG push button LED is on Nameplate of the bell button module ON...

Page 8: ...station sound1 Release 2b alternatively Via floor push button indoor station is not available 6s Press the floor push but ton two times every time a ring tone sounds Press the button until a negative...

Page 9: ...nplate of the bell button module blinks Programming mode of the system is switched on 2 Delete a button 6s Press the button until a negative and positive acknowledgement tone sounds 1 Release 3 End od...

Page 10: ...lates DIN A4 Open and close the module the win clipTM system The device is equipped with the win clipTM system thus opening and closing can be real ised without any screws Open the module 1 Push the e...

Page 11: ...trolSysteme AG TCS Hotline Deutschland hotline tcsag de Subject to technical changes www tcsag de PI_AMI1090x uk 1A Accessory Short text Article number Maintenance package FBI1210 0 Laser film foil ma...

Page 12: ...ject to technical changes www tcsag de PI_AMI1090x uk 1A Service Send your questions and inquiries to hotline tcsag de Headquarters TCS T rControlSysteme AG Geschwister Scholl Str 7 D 39307 Genthin Ph...

Reviews: