TCE Group SRL
|
VIA G. DI VITTORIO - 35046 BORGO VENETO (PADOVA)
–
ITALIA
WWW.TCECHARGERS.COM
AGM2 charging curve
Curva di carica AGM2
S1:
The current rises upon reaching I1=10A in
“
soft start
”
mode.
S2:
The current remains constant at 10A until reaching the
U1 = 2.4 V/cell threshold or reaches the maximum allowed
time for this phase of 9h.
S3:
Upon reaching 2.45 V/cell the current remains constant
I2=6A until U2=2.45 V/cell is reached or reaches the
maximum allowed time for this phase of 2h.
S4:
The voltage remains constant U2=2.45 V/cell, the
current drops to I3=1.6A or reaches the maximum allowed
time for this phase of 2h.
S5:
The current is limited to I3=0.8A and the voltage
remains constant at U3=2.3 V/cell. Maximum allowed time
for this phase is 4h.
Charging information
Maximum charging time: 14 ore
Max V/cell: 2.45 V/cell
Floating: 2.3 V/cell
S1:
La corrente cresce fino a I1
= 10A in modalità “soft start”
.
S2:
La corrente rimane costante a 10A fino al raggiungimento
di U1=2.4 V/cella o raggiunge il tempo massimo concesso per
questa fase di 9 ore.
S3:
La corrente rimane costante I2=6A fino a raggiungere la
soglia di U2=2.45 V/cella o raggiunge il tempo massimo
concesso per questa fase di 2 ore.
S4:
La tensione rimane costante U2 = 2.45 V/cella, la corrente
scende fino a I3=1.6A o raggiunge il tempo massimo concesso
per questa fase di 2 ore.
S5:
La corrente viene limitata a I3 = 0.8A e la tensione rimane
costante a U3 = 2.3 V/cella. Durata massima concessa per
questa fase è di 4 ore.
Informazioni di carica
Tempo di carica massimo: 14 ore
Max V/Cella: 2.45 V/cella
Floating: 2.3 V/Cella