TCE Group SRL
|
VIA G. DI VITTORIO - 35046 BORGO VENETO (PADOVA)
–
ITALIA
WWW.TCECHARGERS.COM
AGM1 charging curve
Curva di carica AGM1
S1:
The current rises upon reaching I1=10A in
“
soft start
”
mode and remains constant upon reaching U1=2.38 V/Cell
or reaches the maximum allowed time for this phase of 8h.
S2
: The voltage remains constant U1=2.38V/Cell, the
current drops until it reaches I2=1.6A or reaches the
maximum allowed time for this phase of 6h.
S3:
The current is limited to I3=0.8A and the voltage
remains constant at U2=2.25 V/cell. Maximum allowed
time for this phase is 4h.
Charging information
Maximum charging time: 14 ore
Max V/cell: 2.38 V/cell
Floating: 2.25 V/cell
S1:
La corrente cresce a I1=
10A in modalità “soft start” fino al
raggiungimento di U1=2.38 V/cella o raggiunge il tempo
massimo concesso per questa fase di 8 ore.
S2:
La tensione rimane costante U1=2.38 V/cella, la corrente
scende fino a I2 = 1.6A o raggiunge il tempo massimo
concesso per questa fase di 6 ore.
S3:
La corrente viene limitata a I3=0.8A e la tensione rimane
costante a U2=2.25 V/cella. Durata massima concessa per
questa fase è di 4 ore.
Informazioni di carica
Tempo di carica massimo: 14 ore
Max V/Cella: 2.38 V/cella
Floating: 2.25 V/Cella