TCE Group SRL
|
VIA G. DI VITTORIO - 35046 BORGO VENETO (PADOVA)
–
ITALIA
WWW.TCECHARGERS.COM
Lead Acid charging curve
–
Light Duty
Curva di carica Piombo Acido
–
Trazione leggera
S1:
The current rises upon reaching I1=10A in
“
soft start
”
mode.
S2:
The current remains constant at 10A until reaching the
U1=2.4 V/cell threshold or reaches the maximum allowed
time for this phase of 8h.
S3:
Upon reaching 2.4 V/cell the current drops until it
reaches I2=2.1A or reaches the maximum allowed time for
this phase of 4,5h.
S4:
The current remains constant I2=2.1A, the voltage
remains inside a predetermined value. Maximum allowed
time for this phase is 4h.
Charging information
Maximum charging time: 14 ore
Max V/cell: 2.4 V/cell
Floating: 2.4 V/Cell + 0.1V Max per hour
S1:
La corrente cresce fino ad arrivare ad I1 = 10A in modalità
“soft start”
.
S2:
La corrente rimane costante a 10A fino al raggiungimento
di U1=2.4 V/cella o raggiunge il tempo massimo concesso per
questa fase di 8 ore.
S3:
Al raggiungimento dei 2.4 V/cella, la corrente viene ridotta
fino a raggiungere I2=2.1A o raggiunge il tempo massimo
concesso per questa fase di 4,5 ore.
S4:
La corrente rimane costante I2=2.1A, la tensione rimane
all’interno di un valore predefinito
o raggiunge il tempo
massimo concesso per questa fase di 4 ore.
Informazioni di carica
Tempo di carica massimo: 14 ore
Max V/Cella: 2.4 V/cella
Floating: 2.4 V/Cella + 0.1V Max per ora