background image

 EN

 

 

 

Step 1: 

connect the charger to the mains voltage with battery not connected. At this point, the charger will turn on and the LED 

will flash red and green alternately for 10 seconds to then completely turn off. The LED will remain off for about 5 minutes during 

which the “wait for replacement curve” status will be automat

ically activated (Note: this status will be kept for 5 minutes, at the 

end of these 5 minutes if the charger doesn’t receive any external command from the remote control, it will automatically rev

ert 

to the stand-by status waiting for the battery to be connected). If the battery is connected within the 

“wait

 for replacement 

curve” 

status, the charger will begin the charge with the previously set profile; 

 

Step 2

: press the “on / off” red button on the remote control to enter the “password block” 

status; 

 

Step 3

: enter the password (default password is 1234). If the password is correct, the LED will turn yellow. 

 

Step 4

: press the 

“Back”

 blue button to access the 

“profile

 

selection”

 status to be able to insert the number in correspondence of 

the wanted curve (see data sheet below) 

 

Step  5

: once  selected  from  the  data  sheet  below  the  wanted  profile,  press  the correspondent  number  on  the remote-control 

keypad to access the 

“profile

 

confirmation”

 status in which the LED will flash based on the selected profile (see below description 

“Profile  selection  LED flashing  code”).  At  this  point,  the  charger  after  flashing  based  on  the  programmed  profile,  the  LED  wi

ll 

completely turn off to indicate that the selection was successful. In case during the operation an issue occurred, the LED will turn 
red. Unplug the charger from the mains voltage and repeat the whole procedure; 

 

Step 6

: to allow the charger to definitively memorize the charging profile selected, unplug the mains  voltage plug. Connect the 

battery and the mains voltage plug to use the charger normally. 

 

Profile Nr. 

Type of Battery 

MAX V/Cell 

Additional Information 

Lead Acid 

2.68 

Heavy Duty 

Lead Acid 

2.4 

Light Duty 

GEL 

2.35 

 

AGM1 

2.38 

 

AGM2 

2.45 

IIUU 

 

CURVE SELECTION LED VISUALIZATIONS 

 
 
 

MOD.  NEOS 12/10 

 24/10 

 
Curva 0 

 Verde prolungato 

 

Curva 1 

 Verde - Giallo 

 

Curva 2 

 Verde 

 Giallo 

 Giallo 

 

Curva 3 

 Verde 

 Giallo 

 Giallo 

 Giallo 

 

Curva 4 

 Verde 

 Giallo 

 Giallo 

 Giallo 

 Giallo 

 

MOD.  NEOS 24/30 

 
Curva 0 

 Verde - Giallo 

 

Curva 1 

 Verde 

 Giallo 

 Giallo  

 

Curva 2 

 Verde 

 Giallo 

 Giallo - Giallo 

 

Curva 3 

 Verde 

 Giallo 

 Giallo 

 Giallo - Giallo 

 

Curva 4 

 Verde 

 Giallo 

 Giallo 

 Giallo 

 Giallo 

 Giallo 

 

Note: Start counting from the first yellow after the green flashing 

 
 

TCE Group SRL

 

Via G. di Vittorio, 5/9 

Tel.: 

+39 0429 89290 

35046 Borgo Veneto (Padova) 

Mail

[email protected] 

Italia 

Web: 

www.tcechargers.com 

 

Summary of Contents for NEOS 12/10

Page 1: ...Instruction manual Curve changing for infrared models Manuale istruzioni Cambio curva per modelli con infrarosso Mod NEOS 12 10 24 10 Mod NEOS 24 30 Model 12 10 24 10 Model 24 30 ...

Page 2: ...eypad to access the profile confirmation status in which the LED will flash based on the selected profile see below description Profile selection LED flashing code At this point the charger after flashing based on the programmed profile the LED will completely turn off to indicate that the selection was successful In case during the operation an issue occurred the LED will turn red Unplug the char...

Page 3: ...a tabella la curva desiderata premere il numero corrispondente nel tastierino del telecomando entrando così nello stato di conferma della curva in cui la spia luminosa lampeggia a seconda della curva scelta vedi descrizione sottostante visualizzazione LED curva A questo punto il caricabatterie dopo aver lampeggiato in base alla selezione il LED si spegnerà ad indicare che la scelta è avvenuta con ...

Page 4: ...TCE Group SRL VIA G DI VITTORIO 35046 BORGO VENETO PADOVA ITALIA WWW TCECHARGERS COM Standard charging curves Mod NEOS 12 10 24 10 Infrared Curve di carica standard Mod NEOS 12 10 24 10 Infrarosso ...

Page 5: ...or the maximum allowed time for this phase of 4h is over Charging information Maximum charging time 14 hours Max V Cell 2 68 V cell Floating 2 55 V cell S1 La corrente cresce da I1 2A fino a I2 10A in modalità soft start S2 La corrente rimane costante a 10A fino al raggiungimento di U1 2 45 V cella o raggiunge il tempo massimo concesso per questa fase di 8 ore S3 Al raggiungimento dei 2 45 V cella...

Page 6: ...imum allowed time for this phase is 4h Charging information Maximum charging time 14 ore Max V cell 2 4 V cell Floating 2 4 V Cell 0 1V Max per hour S1 La corrente cresce fino ad arrivare ad I1 10A in modalità soft start S2 La corrente rimane costante a 10A fino al raggiungimento di U1 2 4 V cella o raggiunge il tempo massimo concesso per questa fase di 8 ore S3 Al raggiungimento dei 2 4 V cella l...

Page 7: ...V cell Maximum allowed time for this phase is 4h Charging information Maximum charging time 14 ore Max V cell 2 35 V cell Floating 2 25 V cell S1 La corrente cresce fino ad arrivare ad I1 10A in modalità soft start e rimane costante fino al raggiungimento di U1 2 35 V cella o raggiunge il tempo massimo concesso per questa fase di 8 ore S2 La tensione rimane costante U1 2 35 V cella la corrente sce...

Page 8: ...onstant at U2 2 25 V cell Maximum allowed time for this phase is 4h Charging information Maximum charging time 14 ore Max V cell 2 38 V cell Floating 2 25 V cell S1 La corrente cresce a I1 10A in modalità soft start fino al raggiungimento di U1 2 38 V cella o raggiunge il tempo massimo concesso per questa fase di 8 ore S2 La tensione rimane costante U1 2 38 V cella la corrente scende fino a I2 1 6...

Page 9: ... at U3 2 3 V cell Maximum allowed time for this phase is 4h Charging information Maximum charging time 14 ore Max V cell 2 45 V cell Floating 2 3 V cell S1 La corrente cresce fino a I1 10A in modalità soft start S2 La corrente rimane costante a 10A fino al raggiungimento di U1 2 4 V cella o raggiunge il tempo massimo concesso per questa fase di 9 ore S3 La corrente rimane costante I2 6A fino a rag...