EN
Step 1:
connect the charger to the mains voltage with battery not connected. At this point, the charger will turn on and the LED
will flash red and green alternately for 10 seconds to then completely turn off. The LED will remain off for about 5 minutes during
which the “wait for replacement curve” status will be automat
ically activated (Note: this status will be kept for 5 minutes, at the
end of these 5 minutes if the charger doesn’t receive any external command from the remote control, it will automatically rev
ert
to the stand-by status waiting for the battery to be connected). If the battery is connected within the
“wait
for replacement
curve”
status, the charger will begin the charge with the previously set profile;
Step 2
: press the “on / off” red button on the remote control to enter the “password block”
status;
Step 3
: enter the password (default password is 1234). If the password is correct, the LED will turn yellow.
Step 4
: press the
“Back”
blue button to access the
“profile
selection”
status to be able to insert the number in correspondence of
the wanted curve (see data sheet below)
Step 5
: once selected from the data sheet below the wanted profile, press the correspondent number on the remote-control
keypad to access the
“profile
confirmation”
status in which the LED will flash based on the selected profile (see below description
“Profile selection LED flashing code”). At this point, the charger after flashing based on the programmed profile, the LED wi
ll
completely turn off to indicate that the selection was successful. In case during the operation an issue occurred, the LED will turn
red. Unplug the charger from the mains voltage and repeat the whole procedure;
Step 6
: to allow the charger to definitively memorize the charging profile selected, unplug the mains voltage plug. Connect the
battery and the mains voltage plug to use the charger normally.
Profile Nr.
Type of Battery
MAX V/Cell
Additional Information
0
Lead Acid
2.68
Heavy Duty
1
Lead Acid
2.4
Light Duty
2
GEL
2.35
3
AGM1
2.38
4
AGM2
2.45
IIUU
CURVE SELECTION LED VISUALIZATIONS
MOD. NEOS 12/10
–
24/10
Curva 0
–
Verde prolungato
Curva 1
–
Verde - Giallo
Curva 2
–
Verde
–
Giallo
–
Giallo
Curva 3
–
Verde
–
Giallo
–
Giallo
–
Giallo
Curva 4
–
Verde
–
Giallo
–
Giallo
–
Giallo
–
Giallo
MOD. NEOS 24/30
Curva 0
–
Verde - Giallo
Curva 1
–
Verde
–
Giallo
–
Giallo
Curva 2
–
Verde
–
Giallo
–
Giallo - Giallo
Curva 3
–
Verde
–
Giallo
–
Giallo
–
Giallo - Giallo
Curva 4
–
Verde
–
Giallo
–
Giallo
–
Giallo
–
Giallo
–
Giallo
Note: Start counting from the first yellow after the green flashing
TCE Group SRL
Via G. di Vittorio, 5/9
Tel.:
+39 0429 89290
35046 Borgo Veneto (Padova)
Mail:
Italia