21
Model C043
Operating Procedures
150629
Priming
KEEP FINGERS OUT OF FILL AND
DISCHARGE OPENINGS!
Failure to do so may
result in severe personal injury, contaminated
product, or component damage.
Step 1
IMPORTANT:
Verify that the flow adjustment knob
is in the CLOSE position and the beater motor
switch is in the OFF position. The draw arm plate
must be closed.
Figure 32
Note:
The flow adjustment knob is used to adjust
the flow of mix. Turning the adjustment knob
clockwise increases the flow. A counter-clockwise
turn decreases the flow. Adjust the mix flow as
needed to maintain proper product consistency.
Step 2
On the front half of the hoppers, install the hopper
covers that have the raised lip.
Figure 33
Step 3
Place the hopper refrigeration knob in the ON
position and set the timer for 30 minutes.
Figure 34
Step 4
After 30 minutes have expired, fill the hopper with
fresh mix.
Note: Use only FRESH MIX when priming the
freezer.